Ricoh D143 Field Service Manual page 1099

Table of Contents

Advertisement

3241
[Background Potential Setting]
001 Coefficient: Bk
002 Coefficient: M
003 Coefficient: C
004 Coefficient: Y
005 Offset: Bk
006 Offset: M
007 Offset: C
008 Offset: Y
[LD Power Setting]
3242
Adjusts the coefficient for LD power control value at the process control.
001 StdSpd:Coefficient: Bk
002 StdSpd:Coefficient: M
003 StdSpd:Coefficient: C
004 StdSpd:Coefficient: Y
005 StdSpd:Offset: Bk
006 StdSpd:Offset: M
007 StdSpd:Offset: C
008 StdSpd:Offset: Y
009 MidSpd:coef:Bk
010 MidSpd:Coef:M
011 MidSpd:Coef:C
012 MidSpd:Coef:Y
013 MidSpd:offset:Bk
*ENG
These are parameters for calculating the charge
bias referring to the development bias at process
*ENG
control.
[-1000 to 1000 / 0 / 1 /step]
*ENG
DC charge bias = Development bias x (1 +
*ENG
0.001 x these vales) + SP3-241-005 to -008
*ENG
These are additional values for calculating the
charge bias referring to the development bias at
*ENG
process control.
[0 to 255 / 140 / 1 V/step]
*ENG
DC charge bias = Development bias x (1 +
*ENG
0.001 x SP3-241-001 to -004) + these values
*ENG
*ENG
[-1000 to 1000 / 124 / 1 /step]
*ENG
*ENG
*ENG
*ENG
[-1000 to 1000 / 4 / 1 /step]
*ENG
*ENG
*ENG
[-1000 to 1000 / 118 / 1 /step]
*ENG
[-1000 to 1000 / 117 / 1 /step]
*ENG
[-1000 to 1000 / 79 / 1 /step]
*ENG
[-1000 to 1000 / 92 / 1 /step]
*ENG
[-1000 to 1000 / 47 / 1 /step]
Main SP Tables-3
175

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D144Ap-c3

Table of Contents