Power specifications

Although battery life varies depending on the type of test,
tions for the battery life and the specifications for the AC adapter.
Table 15 Power specifications
Parameter
Battery operating time
Battery charging time
Unit power input
Power supply input
Power supply output

Electrical Ethernet specifications

The electrical Ethernet applications use the RJ-45 jacks. The 10/100/1000 Base-T/Tx
interfaces conform to the IEEE 802.3 electrical requirements.
Table 16
Table 16 10/100/1000 Mb/s interface specifications
Specification
Cable
Table 17
Table 17 Electrical rates
Rate
10Base-T Ethernet
100Base-T Ethernet
1000Base-T Ethernet

Clock source (Timing) specifications

Table 18
Table 18 Timing specifications for SC 4800
Clock Source
Internal reference
March 2018
5800v1 and v2, 4800
2-5 hours depending on the
application
Approximately 7 hours from empty
12VDC, 60 Watt Max
100 to 240 VAC, 50/60 Hz,
auto-sensing
12VDC, 5 AMP Max
lists the electrical specifications for the 10/100/1000 Mb/s interface.
Description
CAT5e 100-Ohm STP cable, < 100 meters
lists the electrical Ethernet rates supported.
lists internal and external timing specifications for 4800.
T-BERD/MTS/SC Getting Started Guide
22046537, Rev. 016
T-BERD / MTS 5800 and Smart Class 4800 specifications
5800-100G, 5882
For 5800-100G: 1-3 hours.
For 5882: 2-5 hours.
Approximately 3 hours from empty
19VDC, 160 Watt
100 to 240 VAC, 50/60 Hz, auto-
sensing
19VDC, 8.5 AMP
Mbps
10
100
1000
Description
accuracy ±1.5 ppm, ±1 ppm per year aging
Appendix A Specifications
Table 15
provides specifica-
Page 163