Viavi T-BERD MTS 5800 Getting Started Manual page 259

T-berd/mts/sc getting started guide
Hide thumbs Also See for T-BERD MTS 5800:
Table of Contents

Advertisement

Structured test signals (for SDH as described in ITU-T Recommendation O.172)
Sine wave modulation
Standard filters: Highband
Measurement error
The stated measurement error applies without restriction to standard range, for values
>25 UIp in extended range.
Maximum measurement error: ± R % of reading ± W
The value for W (fixed error) is taken from
can be taken from ITU-T Recommendations O.172 (04/2005) and O.173 (03/2003) as
applicable.
Table 159 W (fixed error)
Range
Standard range
1. Mapping SDH VC-4/SONET STS-1, payload pattern PRBS31, environmental temperature +20°C to +30°C.
RMS jitter
This section describes the RMS jitter specifications.
Range and resolution
Table 160
Table 160 RMS range and resolution
(peak-peak)
RMS range
Resolution
Measurement accuracy
Table 161
Table 161 RMS jitter measurement accuracy
Item
Standard range
Extended range
Integration time
1. The value R (variable error) is taken from ITU-T Recommendation O.172 (04/2005) and O.173 (03/2003) as appli-
cable.
March 2018
Wide-band Filter
W in UIpp
0.035
describes the RMS range and resolution.
Standard range
0 to 25 UI
0.0001 UI
describes the RMS jitter measurement accuracy.
Description
± R% of measured value ± 0.003 UI
± R% of measured value ± 0.05 UI
1 second
T-BERD/MTS/SC Getting Started Guide
22046537, Rev. 016
Table
159. The value for R (variable error)
W in UIpp
1
0.5
Extended range
0 to 400 UI
0.01 UI
Appendix A Specifications
Jitter and Wander specifications
Extended-band Filter
1
1
Page 235