Sign In
Upload
Manuals
Brands
Viavi Manuals
Test Equipment
SmartClass Fiber OLTS-85
Viavi SmartClass Fiber OLTS-85 Manuals
Manuals and User Guides for Viavi SmartClass Fiber OLTS-85. We have
2
Viavi SmartClass Fiber OLTS-85 manuals available for free PDF download: Operating Manual, User Manual
Viavi SmartClass Fiber OLTS-85 Operating Manual (139 pages)
Fiber Optical Loss Test Sets
Brand:
Viavi
| Category:
Test Equipment
| Size: 7.26 MB
Table of Contents
Table of Contents
3
Introduction
6
Enterprise Structured Cabling Workflow
6
OLTS-85/OLTS-85P Loss Test Set
8
OLTS-85/OLTS-85P Light Sources
9
Operating Manual Update
10
Symbols Used in this Operating Manual
11
Safety Information
13
Warning Symbols on the Unit
13
Proper Usage
13
Laser Safety
14
Battery Operation
14
Ventilation
15
PS4 Universal AC/DC Power Supply
15
Getting Started
17
Unpacking the Instrument
17
Connecting Optical Cables
25
Basic Operation
27
Switching the Instrument On/Off
27
Operator Control Panel
27
Menus and Display Elements
28
Navigating in the Menus
34
Displaying Application Information
34
Changing System Settings
35
Wifi Menu (Optional)
39
Bluetooth Menu (Optional)
39
Installing a Software Option
39
Updating the Firmware
40
Creating Screenshots
40
Managing Projects
42
Test-Tool Mode
42
Workflow Mode
45
Loss /Length Test Operation
48
General Information
48
Adjusting General Test Settings
49
"Adjusting General Test Settings
49
Defining a Test Configuration
52
"Defining a Test Configuration
52
Referencing
55
"Referencing
55
Running and Viewing a Loss/Length Test
58
"Running and Viewing a Loss/Length Test
58
"Saving Loss/Length Test Results
62
Saving Loss/Length Test Results
62
Loss Test Operation
64
General Information
64
Selecting a Port and Wavelength
65
Selecting the Measurement Mode
65
Referencing
66
Pass/Fail Indication
68
Switching On/Off the Laser
68
Performing the Measurement
69
Viewing Test Results
69
Saving Loss Test Results
70
Powermeter Operation
72
General Information
72
Setting and Selecting Wavelengths
72
Enabling Auto- Mode
75
Selecting and Changing the Power Display Mode
76
Displaying Relative Power Level
76
Saving Powermeter Test Results
77
Source Operation
79
General Information
79
Selecting an Output Port and Wavelength
81
About Auto- Mode
81
Selecting a Modulation or Auto- Mode
82
Setting the Power Level
83
Switching On/Off the Laser
84
Measuring Loss with
85
Easuring Oss with Ource Owermeter
85
General Information
85
Performing the Measurement
85
Viewing Test Results
86
Saving Loss Test Results
87
Probe /Pcm Operation
89
General Information
89
The Build in Patch Cord Microscope (PCM)
89
The External P5000I Digital Probe
90
Basic Settings
92
Selecting a Profile and Adapter/Tip
94
Operation
95
Saving Probe/Pcm Results
97
Workflow Mode
99
Performing a Measurement in Workflow Mode
99
These Steps Are Described in Detail in the Following Sections
99
If a Test Has Failed / Repeating a Test
103
Managing Workflow Projects
104
Data Management
105
Saving Results
105
Selecting Test Results in Test-Tool or Workflow Mode
105
Data Management of Loss/Length Tests
105
Data Management of Loss and Powermeter Tests
107
Data Management of Probe and PCM Tests
110
Exporting Results to USB
113
Importing Test Results from Another Unit
114
Making a Report
114
Maintenance
115
Cleaning the Test Port
115
Cleaning the Instrument
115
Appendix - Referencing Methods
116
Loopback and Remote Referencing
116
Remote Control
123
Environmental Compliance
124
Specifications
126
General Specifications
126
Power Meter Specifications
127
Light Source Specifications
127
Tier 1 Specifications
128
Patch Cord Microscope Specifications
128
Ordering Information
129
OLTS-85/OLTS-85P Stand Alone Units
129
Included Items
129
Accessories
130
Advertisement
Viavi SmartClass Fiber OLTS-85 User Manual (88 pages)
Brand:
Viavi
| Category:
Test Equipment
| Size: 4.76 MB
Table of Contents
Table of Contents
3
Introduction
5
OLTS-85 Loss Test Set
5
OLTS-85 Light Sources
6
Operating Manual Update
7
Symbols Used in this Operating Manual
8
Safety Information
10
Warning Symbols on the Unit
10
Proper Usage
10
Laser Safety
11
Battery Operation
11
Ventilation
12
PS4 Universal AC/DC Power Supply
12
Getting Started
14
Unpacking the Instrument
14
Connecting Optical Cables
21
Basic Operation
23
Switching the Instrument On/Off
23
Operator Control Panel
23
Display Elements
24
Navigating in the Menus
25
Getting Help and Information
25
Configuring the Instrument
26
Software Options
30
Tier 1 Loss Test Operation
32
Tier 1 Loss Test
32
Referencing Methods
37
Pass/Fail Indication
45
Powermeter Operation
46
General Information
46
Powermeter Measurement
46
Laser Operation
51
General Information
51
Selecting a Laser Source
53
Auto Λ Feature
53
Selecting a Mode
54
Setting the Power Level
56
Switching On/Off the Laser
57
Probe /Pcm Operation
58
General Information
58
Patch Cord Microscope (PCM)
58
FMAE Series Adapters for the PCM
59
Features Available with the P5000I Digital Probe
59
Quickcapture™ Key
61
File Toolbar
61
Configuring the Digital Probe
62
Memory Management
66
General Information
66
Selecting the Project to Save or Display Results
68
Saving Results
68
Displaying Stored Results
70
Using the Link Data Mode
71
Clearing the Memory
72
Making a Report
74
Maintenance
75
Cleaning the Test Port
75
Cleaning the Instrument
75
Specifications
77
General Specifications
77
Power Meter Specifications
78
Light Source Specifications
78
Tier 1 Specifications
79
Patch Cord Microscope Specifications
79
Ordering Information
80
OLTS-85 Optical Loss Test Set
80
Included Items
80
Accessories
81
Advertisement
Related Products
Viavi SmartClass OLTS-85P
Viavi OLP-88
Viavi OLP-88P
Viavi SmartClass OLP-37
Viavi SmartClass OLS-85P
Viavi SmartClass OLP-85 Series
Viavi SmartClass OLP-85P Series
Viavi SmartPocket OLP-39G
Viavi SmartPocket OLP-39X
Viavi OLP-82P
Viavi Categories
Test Equipment
Measuring Instruments
Control Unit
Server
Microscope
More Viavi Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL