Festo CPX-FB14 Description page 25

Terminal cpx, bus node, canopen networkprotocol
Hide thumbs Also See for CPX-FB14:
Table of Contents

Advertisement

1. Installation
Operating mode
Remote I/O operating mode
All functions of the CPX terminal are controlled directly by
the CANopen Master. An FEC or CEC that may be integrated
into the CPX terminal works as a passive function module
without controller.
Remote controller operating mode
An FEC or CEC integrated into the CPX terminal takes over
I/O control. This operating mode is only useful if an FEC or
CEC is integrated into the CPX terminal.
Tab. 1/1:
DIL switch 1: (operating mode)
Festo P.BE-FB14-EN en 1411d English
Setting the operating mode with DIL switch
You can set the operating mode of the bus node with switch
element 1 of DIL switch 1:
1
Setting DIL switch 1
DIL 1.1: OFF
DIL 1.2: OFF
(factory setting)
DIL 1.1: ON
DIL 1.2: OFF
1-11