2. Commissioning
Index (hex)
6206
Subindex 1 ... 10
h
Bit 0 ... 7
6207
Subindex 1 ... 10
h
Bit 0 ... 7
Tab. 2/46: Statuses of the valves and outputs in case of error
2-54
The statuses of the valves and outputs of the CPX valve ter
minal can be defined in case of error.
Note
With Index 6206 you can define the outputs which are to
assume a defined status in the event of a fault.
With Index 6207 you can define the status which the fixed
outputs are to assume in the event of a fault.
The settings do not become active until the CPX valve
terminal is put into the operational mode.
After each switching on or after each reset (hardware
initialization), the default values will automatically be
accepted and any maskings will be overwritten.
The following applies:
Definition
0 = status of the output is retained
1 = output assumes the status defined in Index 6207
0 = output is reset
1 = output is set
Festo P.BE-FB14-EN en 1411d English