2. Commissioning
System parameters
Index
Sub
Designa
(hex)
index
tion
2400
0
System
parameters
1
Parameter
byte 0
2
Parameter
byte 1
3
Parameter
byte 2
4 ... 8
Reserved
1)
Note: The bus node supports only the mode "Faultmode benutzen" or "Assume fault mode"
(è Festo Maintenance Tool).
The error characteristics of the individual outputs are parameterised through the objects 6206
and 6207. Outputs whose error characteristics have not been parameterised are reset in case of
error.
Outputs whose error characteristics have not been parameterised are reset in case of error.
(Information on parameterisation of the outputs' error characteristics è Tab. 2/46)
2)
At system start with saved parameterisation, only the objects 2000 ... 5FFF are loaded. The ob
jects 6000 ... are always loaded with the default settings after power-on.
Tab. 2/59: System parameters
Festo P.BE-FB14-EN en 1411d English
Type Attr. Val
ues
(hex)
U8
ro
8
rw
0 ... FF
0 ... FF
0 ... FF
–
Detailed information on parameters and data can be found in
the CPX system description.
Explanation
Number of entries
Reserved
Monitoring (active/inactive)
1)
Bit 0, 1: not used
Bit 2, 3: force mode
Bit 4, 5: not used
2)
Bit 6, 7: system start
Reserved
Func
tion
no.
–
4400
4401
4402
–
2-77