B. Configuration with CPX node
B.2.2 Configuration with STEP 7
Entry
CPX-CMIX: 6 Byte E/6 Byte A
1)
The maximum number of parameterisation data for the CPX terminal is limited to 234.
Festo P.BE-CPX-CMIX-EN en 1208a
This manual refers to software version V 5.3.
An appropriate device master file (GSD file) must be installed
for configuration.
Proceed as follows for configuration (see Fig. B/8):
1. Add a DP master system 1 and the CPX terminal 2 to
the CPX-FB13, as per the instructions.
2. Fill the configuration table with the modules of your
CPX system.
Open the component "Festo CPX-Terminal" in the
Hardware Catalogue (file \PROFIBUS-DP\Additional Field
Devices\Valves\...) 3.
There are two entries for the CMIX:
Description
CMIX with 6 bytes I / 6 bytes O,
(occupies 3 bytes of parameterisation data)
3. Assign each of the starting addresses in the
"Properties – DP slave" window 4.
This concludes the station selection and configuration.
1)
B-13