A. Technical appendix
A.4
Replacing components
Replacement
... of a CMIX or
CPX terminal
... of drive or
measuring system
... of other
components
Tab. A/12: Replacing components
A-10
When replacing components, observe the instructions in
Tab. A/12.
Description
•
Zero point
Any zero point set is stored in the CMIX and must be reset.
•
Effective stroke length and minimum/maximum position:
The effective stroke length and minimum/maximum position for the poten-
tiometer measuring system type is stored in the CMIX and must be reset.
•
Zero point
Any zero point set is stored in the CMIX and is retained.
•
Effective stroke length and minimum/maximum position:
The effective stroke length and minimum/maximum position for the poten-
tiometer measuring system type is stored in the CMIX and is retained.
Note, however, that the reference system may change when the drive or
measuring system is replaced!
Identical electrical components, such as the sensor interface, can be replaced
without further changes.