Replacing Components; A.4 Replacing Components - Festo CPX-CMIX-M1-1 Manual

Cpx terminal, measurement module
Hide thumbs Also See for CPX-CMIX-M1-1:
Table of Contents

Advertisement

A. Technical appendix
A.4

Replacing components

Replacement
... of a CMIX or
CPX terminal
... of drive or
measuring system
... of other
components
Tab. A/12: Replacing components
A-10
When replacing components, observe the instructions in
Tab. A/12.
Description
Zero point
Any zero point set is stored in the CMIX and must be reset.
Effective stroke length and minimum/maximum position:
The effective stroke length and minimum/maximum position for the poten-
tiometer measuring system type is stored in the CMIX and must be reset.
Zero point
Any zero point set is stored in the CMIX and is retained.
Effective stroke length and minimum/maximum position:
The effective stroke length and minimum/maximum position for the poten-
tiometer measuring system type is stored in the CMIX and is retained.
Note, however, that the reference system may change when the drive or
measuring system is replaced!
Identical electrical components, such as the sensor interface, can be replaced
without further changes.