3. Commissioning

3.4.4 Examples

Step 1
Output data Byte 0
Bit 7 ... 0
00000000 00000000 00000000 00000000 01000000
Hex.
0x00
Description
Not relevant
Input data
Byte 0
Bit 7 ... 0
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX 00000000
Hex.
0xXX
Description
X: Not relevant
Step 2
Output data Byte 0
Bit 7 ... 0
00000000 00000000 00000000 00000000 01100000
Hex.
0x00
Description
Not relevant
Input data
Byte 0
Bit 7 ... 0
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX 00100000
Hex.
0xXX
Description
X: Not relevant
3-14
Potentiometer commissioning
Bring measuring system into the lower stroke-limiting
mechanical stop of the drive.
Byte 1
Byte 2
0x00
0x00
Byte 1
Byte 2
0xXX
0xXX
Accept lower stop.
Byte 1
Byte 2
0x00
0x00
Byte 1
Byte 2
0xXX
0xXX
Byte 3
Byte 4
0x00
0x40
Bit 6, 7: Min. position
Byte 3
Byte 4
0xXX
0x00
Bit 5: No acceptance
Bit 7: No error
Byte 3
Byte 4
0x00
0x60
Bit 5: Accept position
Bit 6, 7: Min. position
Byte 3
Byte 4
0xXX
0x20
Bit 5: Pos. accepted
Bit 7: No error
Festo P.BE-CPX-CMIX-EN en 1208a
Byte 5
00000000
0x00
Reserved
Byte 5
00000000
0x00
Reserved
Byte 5
00000000
0x00
Reserved
Byte 5
00000000
0x00
Reserved

Advertisement

Table of Contents
loading