I/O Diagnostic Interface And Diagnostic Memory - Festo CPX-CMIX-M1-1 Manual

Cpx terminal, measurement module
Hide thumbs Also See for CPX-CMIX-M1-1:
Table of Contents

Advertisement

4. Diagnosis

4.4.3 I/O diagnostic interface and diagnostic memory

Diagnostic memory data (10 bytes per entry, max. 40 entries)
Byte
Designation
1
Days [day]
2
Hours [h]
3
Minutes [m]
4
Seconds [s]
5
Milliseconds [ms]
6
Module code
7
Module position
[Pos]
8
Channel number
9
Error number [FN]
10
Following channels
1)
d (diagnostic event) [NB] = 0 ... 39; most current diagnostic event = 0
Tab. 4/6:
Diagnostic memory data of the CMIX
Festo P.BE-CPX-CMIX-EN en 1208a
A range of different diagnostic information is accessible via
the I/O diagnostic interface and the diagnostic memory of the
CPX terminal.
Diagnostic memory data
(Handheld and I/O diagnostic interface)
The specific representation of diagnostic messages of the
CMIX in the diagnostic memory of the CPX terminal occurs as
shown in Tab. 4/6.
Description
Time information for the reported
error, measured from the point when
the power supply was switched on
(CPX standard).
Module code of the CMIX: 180
Module number of the CPX module
that signaled the error
Bit 7
6
5 ... 0
Description
1
0
0 ... 0
Error in
I-channel 0
CPX error number 108
(see section 4.1)
Always 0 for the CMIX
Instructions on diagnosis with the I/O diagnostic interface
can be found in the CPX system manual.
Function no.
Value
3488 + n
0 ... 255
n = 10 * d + 0
0 ... 23
0 ... 59
0 ... 59
0 ... 99
(128 ... 227)
0 ... 255
n = 10 * d + 5
0 ... 47
n = 10 * d + 6
128
n = 10 * d + 7
(0 ... 255)
108
n = 10 * d + 8
(0 ... 255)
0 (0 ... 63)
n = 10 * d + 9
1)
4-11

Advertisement

Table of Contents
loading

Table of Contents