B. Configuration with CPX node

B.2.3 Parameterisation

Festo P.BE-CPX-CMIX-EN en 1208a
The CMIX does not have any module parameters.
CPX parameter "Analogue process value presentation"
Some CPX bus nodes (e.g. CPX-FB13, FB33, FB34 and FB35)
support the global system parameter "Analogue process
value presentation" (system table function number 4402,
bit 7):
Value "0":
INTEL (LSB-MSB) – default
Value "1": MOTOROLA (MSB-LSB)
Fig. B/9: CPX parameter "Analogue process value
presentation"
Note the byte order of the actual and setpoint values when
using the INTEL format; see section B.2.4.
General information can be found in section 3.3.2.
B-15