4. Diagnosis
Function number
2008+m*4+1
Error no.
Description
16
Module code not permitted or incorrect
module
(Handheld: [Module code incorrect] )
– The string allocation stored in the CMIX is
different from the configuration stored in
the CPX bus node or the CPX-FEC
Tab. 4/2:
Additional error message of the CPX terminal

4.1.2 Acknowledging errors

4-4
Error numbers on the CPX terminal
All CMIX errors are also signaled as CPX error message 108
(measuring system error). This can be examined via the I/O
diagnostic interface, for example.
Module diagnostic data
Module error number
Furthermore, the following errors can occur during the com-
missioning phase for the CPX bus node with the parameter
"System start" = "saved parameterising and CPX-FEC system
equipment status" or for the CPX-FEC:
Errors can basically only be acknowledged after the cause of
the error has been rectified.
In order to delete the error:
acknowledge the error with the RESET_FAULT bit
or
switch the operating voltage off and then on again.
Error handling
For the CPX bus node:
Change parameter "System start..."
to "... default parameterisation and
current CPX equipment status"
With the CPX-FEC:
Save the actual configuration as the
set configuration using the FST
software
Festo P.BE-CPX-CMIX-EN en 1208a