Technical Data Cmix - Festo CPX-CMIX-M1-1 Manual

Cpx terminal, measurement module
Hide thumbs Also See for CPX-CMIX-M1-1:
Table of Contents

Advertisement

A. Technical appendix
A.1

Technical Data CMIX

General CMIX
General technical data
Product weight (with CPX-GE-EV-S)
Protection class as per EN 60529, completely
installed, plug connector inserted or provided
with protective cap
Protection against electric shock
(protection against direct and indirect contact as
per IEC/DIN EN 60204-1)
Module code (CPX-specific)
Module identifier (in the handheld)
CMIX power supply
Operating voltage / load voltage
CMIX current consumption
– from operating power supply
Electronics/Sensors (V
Electrical isolation
– between the operating voltage supply for the
electronics/sensors (V
voltage supply for the valves (V
Power failure bridging time
CMIX measuring system connection
Axis string
Number of axis strings / Number of axes
Max. total length (all cables)
Type of axis connection
Festo P.BE-CPX-CMIX-EN en 1208a
)
EL/SEN
) and the load
EL/SEN
)
VAL
See CPX system manual P.BE-CPX-SYS-...
approx. 240 g
IP65
By means of PELV power circuit
(Protected Extra-Low Voltage)
180
CPX-CMIX-M1-1
CMIX Sensor Interface
See CPX system manual P.BE-CPX-SYS-...
Typ. 80 ... 110 mA at 24 V,
max. 110 mA
None
10 ms (for systems with DGCI or DDLI,
a power failure > 1 ms causes error E80)
1 / 1
30 m
Socket M9, 5-pin
A-3

Advertisement

Table of Contents
loading