Sensor Interface Casm - Festo CPX-CMIX-M1-1 Manual

Cpx terminal, measurement module
Hide thumbs Also See for CPX-CMIX-M1-1:
Table of Contents

Advertisement

2. Fitting and installation

2.5.4 Sensor interface CASM

Drive
Displacement
encoder
DGCI, DDLI
permanently installed
or integrated
DNCI, DDPC
integrated
DNC
external,
MLO-POT-...-LWG
DSMI
integrated
DGP(L)
external,
MLO-POT-...-TLF
DNCM
external, fitted on
delivery
Tab. 2/6:
Overview of sensor interfaces and measuring system cables
2-14
The sensor interface type CASM-... has an incoming (S1)
connection; see section 2.5.2.
A corresponding input (S2) for connecting the specific
displacement encoder is also available; see Tab. 2/6.
Sensor interface
(no sensor interface
required)
CASM-S-D3-R7
CASM-S-D2-R3
In principle, other potentiometers can be used: Observe the
following:
The potentiometer must have a connection resistance of
3 ... 20 kΩ.
If the potentiometer has worse values for linearity and
temperature coefficient, the measured value will be less
accurate.
To connect it to the sensor interface, you might have to
fabricate a special cable.
Connecting cable
KVI-CP-3-...
permanently connected to DNCI/DDPC
NEBC-P1W4-K-0,3-N-M12G5
NEBC-A1W3-K-0,3-N-M12G5
Festo P.BE-CPX-CMIX-EN en 1208a