Festo CPX-CMIX-M1-1 Manual page 58

Cpx terminal, measurement module
Hide thumbs Also See for CPX-CMIX-M1-1:
Table of Contents

Advertisement

3. Commissioning
Step 5
Output data Byte 0
Bit 7 ... 0
01110100 10111101 00000000 00000000 00000001
Hex.
0x74
Description
Effective stroke length setpoint value,
example 485 mm (Z 48500
Input data
Byte 0
Bit 7 ... 0
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX 00000000
Hex.
0xXX
Description
X: Not relevant
Step 6
Output data Byte 0
Bit 7 ... 0
01110100 10111101 00000000 00000000 00100001
Hex.
0x74
Description
Effective stroke length setpoint value,
example 485 mm (Z 48500
3-16
Set effective stroke length.
Byte 1
Byte 2
0xBD
0x00
= 0x0000BD74)
d
Byte 1
Byte 2
0xXX
0xXX
Accept effective stroke length.
Byte 1
Byte 2
0xBD
0x00
= 0x0000BD74)
d
Byte 3
Byte 4
0x00
0x01
Bit 0: Unit 0.01 mm
Bit 1: Format 32-bit int.
Bit 2: Position mode
Bit 6, 7: Effective stroke
length
Byte 3
Byte 4
0xXX
0x00
Bit 5: No acceptance
Bit 7: No error
Byte 3
Byte 4
0x00
0x21
Bit 0: Unit 0.01 mm
Bit 1: Format 32-bit int.
Bit 2: Position mode
Bit 5: Accept length
Bit 6, 7: Effective stroke
length
Festo P.BE-CPX-CMIX-EN en 1208a
Byte 5
00000000
0x00
Reserved
Byte 5
00000000
0x00
Reserved
Byte 5
00000000
0x00
Reserved

Advertisement

Table of Contents
loading

Table of Contents