3. Commissioning
Step 3
Output data Byte 0
Bit 7 ... 0
00000000 00000000 00000000 00000000 10000000
Hex.
0x00
Description
Not relevant
Input data
Byte 0
Bit 7 ... 0
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX 00000000
Hex.
0xXX
Description
X: Not relevant
Step 4
Output data Byte 0
Bit 7 ... 0
00000000 00000000 00000000 00000000 10100000
Hex.
0x00
Description
Not relevant
Input data
Byte 0
Bit 7 ... 0
XXXXXXXX XXXXXXXX XXXXXXXX XXXXXXXX 00100000
Hex.
0xXX
Description
X: Not relevant
Festo P.BE-CPX-CMIX-EN en 1208a
Bring measuring system into the upper stroke-limiting
mechanical stop of the drive.
Byte 1
Byte 2
0x00
0x00
Byte 1
Byte 2
0xXX
0xXX
Accept upper stop.
Byte 1
Byte 2
0x00
0x00
Byte 1
Byte 2
0xXX
0xXX
Byte 3
Byte 4
0x00
0x80
Bit 6, 7: Max. position
Byte 3
Byte 4
0xXX
0x00
Bit 5: No acceptance
Bit 7: No error
Byte 3
Byte 4
0x00
0xA0
Bit 5: Pos. accepted
Bit 6, 7: Max. position
Byte 3
Byte 4
0xXX
0x20
Bit 5: Pos. accepted
Bit 7: No error
Byte 5
00000000
0x00
Reserved
Byte 5
00000000
0x00
Reserved
Byte 5
00000000
0x00
Reserved
Byte 5
00000000
0x00
Reserved
3-15