3. Commissioning
Status byte 4 (SCON)
Bit
DE
B0
Error code
ERROR0
B1
ERROR1
B2
ERROR2
B3
ERROR3
B4
Referenz-
REF_OK
punkt
gesetzt
B5
Parameter
ACK
über-
nommen
B6
B7
Fehler
ERROR
3-8
EN
Description
Error code
Error code of the error.
Bit 3 2 1 0
0 0 0 0
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 1
0 1 1 0
1 0 0 0
All other values are reserved.
Reference
Status of referencing (or zero point).
point set
= 0: Reference position is set.
= 1: No reference position set yet.
Acknowl-
Confirmation (handshake) of parameter acceptance.
edge
= 0: No parameter acknowledgement (LOAD_P = 0)
Parameter
= 1: Parameter acknowledged LOAD_P can be reset to 0
Reserved (= 0)
Error
Error bit.
= 0: No error
= 1: Error present; see B0 ... B3
Value Error
0
No error
1
Measuring system is not present/
defect or communication error
or time out (E80)
2
Checksum error in the measuring
system (E81)
3
Under voltage in CMIX module (E52)
5
Impermissible entry of the
effective stroke length (E84)
} 100 ≥ Effective stroke length
≥ 500000
6
Undervoltage in the measuring system
(E85)
8
Measuring system defective (E87)
Festo P.BE-CPX-CMIX-EN en 1208a