Delta AH500 Programming Manual page 711

Hide thumbs Also See for AH500:
Table of Contents

Advertisement

begin to execute from STEP 1. When S
cleared and will begin to execute from the designated STEP of S
3. When M1 is set from OFF to ON, TestSFC1 POU will pause. When S
executing actions and the outputs of the SFC will be cleared, and the system will run the final
scan.
4. When M2 is set from OFF to ON, TestSFC1 POU will execute its actions. When S
the status and the parameters will be cleared, and the system will begin to execute from STEP
2.
5. When M3 is set from OFF to ON, TestSFC2 POU will pause. When S
executing actions of the SFC and the outputs will be kept, and the system will not run the final
scan.
6. When M4 is set from OFF to ON, TestSFC1 POU will execute its actions. When S
the status and the parameters will be kept and will begin to execute from where it pauses.
*SFCRUN will activate SPC POU at the next scan.