13. The flags related to the Ethernet
 SM1001~SM1003, SM1089, SM1090, SM1091, and SM1106~SM1109
SM
number
Connection status of Ethernet
SM1001
Port 1
Connection status of Ethernet
SM1002
Port 2
Connection status of
SM1003
synchronization fiber cable
Maximum MODBUS TCP
SM1089
connetion number has been
reached.
SM1090
The TCP connection is busy.
SM1091
The UDP connection is busy.
SM1106
Ethernet connection error
SM1107
Basic setting error
SM1108
Filter setting error
Basic management of the
TCP/UDP socket─The local port
SM1109
is already used.
Please refer to section 12.2 in AH500 Operation Manual for more information about the LED
indicators and the error codes.
14. The setting of the email sending
 SM1112~SM1113, and SM1116~SM1195
Before sending the email, users have to set the related parameters in the email. If the
setting fails, SM1112 will be set to ON. Besides, SM1113 will be set to ON if the sending of
the email fails.
The triggers (trigger1~trigger8) and the flags (SM1116~SM1195) are described below.
Trigger
Item
Function
1
Email
SM1116
trigger
When the basic setting is incorrect, the flag is set to ON.
switch
SM1117
Email
trigger
When the filter setting is incorrect, the flag is set to ON.
Email
SM1118
trigger
When the trigger is enabled and no mail has been sent, the flag is ON.
status 0
SM1119
Email
trigger
When the trigger is enabled and the last mail has been sent successfully, the flag is
status 1
ON.
Email
SM1120
trigger
When the trigger is enabled and the last mail has been sent in error, the flag is ON.
status 2
Description
Trigger
Trigger
Trigger
2
3
SM1126
SM1136
SM1146
SM1127
SM1137
SM1147
SM1128
SM1138
SM1148
SM1129
SM1139
SM1149
SM1130
SM1140
SM1150
Function
OFF:Ethernet Port 1 is not connected.
ON:Ethernet Port 1 is connected.
OFF:Ethernet Port 2 is not connected.
ON:Ethernet Port 2 is connected.
OFF:Synchronization fiber cable is not
connected.
ON:Synchronization fiber cable is
connected.
ON:Maximum MODBUS TCP connetion
number has been reached.
ON: TCP connection timeout
ON: UDP connection timeout
OFF: The Ethernet auto-negotiation
succeeds.
ON: The Ethernet auto-negotiation fails.
OFF: The basic setting is correct.
ON: The basic setting is incorrect.
OFF: The filter setting is correct.
ON: The filter setting is incorrect.
The flag is ON when the same port is used.
Trigger
Trigger
4
5
6
SM1156
SM1166
SM1157
SM1167
SM1158
SM1168
SM1159
SM1169
SM1160
SM1170
Ch a pt er 2 De v ic es
Trigger
Trigger
7
8
SM1176
SM1186
SM1177
SM1187
SM1178
SM1188
SM1179
SM1189
SM1180
SM1190
2 - 9 1