Delta AH500 Programming Manual page 257

Hide thumbs Also See for AH500:
Table of Contents

Advertisement

API
Instruction code
0209
D
GBIN
Device X
Y
M
S
D
Symbol:
Explanation:
1.
The Gray code in the device specified by S is converted into the binary value, and the
conversion result is stored in the device specified by D.
2.
The instruction is used to convert the Gary code in the absolute position encoder which is
connected to the input terminal of the PLC to the binary value, and the conversion result is
stored in the register which is specified.
3.
The value in the operand S should be within the available range.
The value in the operand S used in the 16-bit instruction should be within the range between 0
and 32,767.
The value in the operand S used in the 32-bit instruction should be within the range between 0
and 2,147,483,647.
Example:
When X0.0 is ON, the Gary code in the absolute position encoder which is connected to the inputs
X0.0~X0.15 is converted into the binary value, and the conversion result is stored in D10.
GRAY CODE 6513
Additional remark:
If the value in S is less than 0, the operation error occurs, the instruction is not executed, SM0 is ON,
and the error code in SR0 is 16#2003.
Operand
S, D
P
S
T
C
HC
D
Pulse instruction 16-bit instruction (5 steps) 32-bit instruction (5 steps)
AH500
S : Source device
D : Conversion result
X0.15
0 0 0 1
b15
H1971=K6513
0 0 0
1
Ch a pt er 6 Ap p l i ed I ns t r uc t i ons
Converting the Gray code into the
binary number
L
SM SR
E
PR
AH500
Word/Double word
Word/Double word
X0
X0.0
0 1
0
1
1
1
0
0
1
0 0
1
b0
1
0
0
1
0
1
1
1
0
0 0 1
Function
K
16# "$"
DF
AH500
6 - 8 9