4.
When users use the instruction, they have to notice that the maximum source value should be
larger than the minimum source value. However, the maximum destination value is not
necessarily larger than the minimum destination value.
5.
When the maximum source value is the same as the minimum source value, the instruction
will not be executed and it will be seen as an operation error; SM0 will be ON and the error
code in SR0 is 16#2012.
6.
If the operand S
used during the execution of the 16-bit instruction is declared in ISPSoft, the
2
data type will be ARRAY [4] of WORD.
7.
If the operand S
used during the execution of the 32-bit instruction is declared in ISPSoft, the
2
data type will be ARRAY [4] of DWORD.