Delta AH500 Programming Manual page 254

Hide thumbs Also See for AH500:
Table of Contents

Advertisement

AH 5 00 Pr ogr am m ing Ma n ua l
API
Instruction code
0206
MMOV
Device X
Y
M
S
D
Symbol:
Explanation:
The data in the 16-bit device S is transmitted to the 32-bit device D. The sing bit which is specified is
copied repeatedly to the destination.
Example:
When X0.0 is ON, the value of b15 in D4 is transmitted to b15~b31 in (D7, D6). The data in (D7, D6)
becomes a negative value.
Plus sign
0
1
Minus sign
1
1
1
1
b 31
6 - 8 6
Operand
S, D
P
S
T
C
HC
D
Pulse instruction 16-bit instruction (5 steps)
AH500
S : Source device
D : Conversion result
b 15
1
1
1
1
1
1
1
1
1
1
1
1
1
1
b 16
b 15
Converting the 16-bit value into the
32-bit value
L
SM SR
E
PR
AH500
Word
Double word
0 0 1 1
0
0
1
0
1 1
1
0 0 0
0
0 0
1
1
0
0
1
1
1
1
0
0 0 1
Function
K
16# "$"
DF
32-bit instruction
b 0
D4
1
D7, D6
b 0