AH 5 00 Pr ogr am m ing Ma n ua l
Example 2:
When X0.0 is ON, the setting value 50 is loaded to the timer T0. When the value of T0 is 25 and
X0.0 is switched from OFF to ON, T0 counts up from 25 to 50, and the contact of T0 is ON.
Example 3:
When X0.0 is ON, the setting value 1000 is loaded to the timer T5. When the value of T5 ,matches
1000, the contact of T5 is ON.
Example 4:
When X0.0 is ON, the setting value 1000 is loaded to the timer T5. When the value of T5 is 500 and
X0.0 is switched from OFF to ON, T0 counts up from 50 to 1000, and the contact of T5 is ON.
Additional remark:
When declare the operand S1 via ISPSoft, the data type is TIMER.
6 - 2 3 0