Classification
Model Name
Analog
input/output
AH06XA-5A
module
AH04PT-5A
Temperature
AH08PTG-5A
measurement
module
AH04TC-5A
AH08TC-5A
AH02HC-5A
AH04HC-5A
AH05PM-5A
Motion control
AH10PM-5A
module
AH15PM-5A
AH20MC-5A
AH10EN-5A
AH15EN-5A
Network
module
AH10SCM-5A
AH15SCM-5A
Description
Conversion time: 150 us/channel
Four-channel analog input module
Hardware resolution: 16 bits
0/1 V~5 V, -5 V~5 V, 0 V~10 V, -10 V~10 V, 0/4 mA~20
mA, and -20 mA~20 mA
Conversion time: 150 us/channel
Two-channel analog output module
Hardware resolution: 16 bits
0/1 V~5 V, -5 V~5 V, 0 V~10 V, -10 V~10 V, and 0/4
mA~20 mA
Conversion time: 150 us/channel
Four-channel four-wire/three-wire RTD
Sensor type: Pt100/Pt1000/Ni100/Ni1000 sensor, and
0~300 Ω input impedance
Resolution: 0.1°C/0.1°F (16 bits)
Four-wire conversion time: 150 ms/channel
Three-wire conversion time: 300 ms/channel
Eight-channel four-wire/three-wire/two-wire RTD
Sensor type: Pt100/Pt1000/Ni100/Ni1000, and 0~300 Ω
input impedance
Resolution: 0.1°C/0.1°F (16 bits)
Conversion time: 20 ms/4 channels and 200 ms/8
channels
Four-channel thermocouple
Sensor type: J, K, R, S, T, E, N, and -150~+150 mV
Resolution: 0.1°C/0.1°F
Conversion time: 200 ms/channel
Eight-channel thermocouple
Sensor type: J, K, R, S, T, E, N, and -150~+150 mV
Resolution: 0.1°C/0.1°F
Conversion time: 200 ms/channel
Two-channel high-speed counter module (200 kHz)
Four-channel high-speed counter module (200 kHz)
Two-axis pulse train motion control module (1 MHz)
Six-axis pulse train motion control module
(Four axes: 1 MHz; Two axes: 200 kHz)
Four-axis pulse train motion control module (1 MHz )
Twelve-axis DMCNET (Delta Motion Control Network)
motion control module (10 Mbps)
It is an Ethernet communication module. It can function as
a mater or a slave. It is equipped with two Ethernet ports,
and supports a Modbus TCP master and EtherNet/IP
(V2.0).
It is an Ethernet communication module. It can function as
a mater or a slave. It is equipped with two Ethernet ports,
and supports a Modbus TCP master and
IEC60870-5-104.
It is a serial communication module with two
RS-485/RS-422 ports, and supports Modbus and UD Link
protocols.
One part of communication is isolated from the other part
of the communication, and one part of power is isolated
from the other part of the power.
It is a serial communication module with two RS-232
ports, and supports Modbus and UD Link protocols.
Ch a pt er 1 In tr od uc t i o n
1 - 7

Advertisement

Table of Contents
loading