API
Instruction code
1511
D
SQR
Device X
Y
M
S
D
Symbol:
Explanation:
1.
The square root of the value in the device specified by S is calculated, and the result is stored
in the device specified by D.
2.
The operation result stored in D is an integer. If the floating-point number is rounded down to
the nearest whole digit, SM601 is ON.
3.
If the operation result stored in D is 0, SM600 is ON.
Example:
When X0.0 is ON, the square root of the value in D0 is calculated, and the result is stored in D10.
Additional remark:
1.
The value in the device specified by S only can be a positive value. If the value in the device
specified by S is a negative value, the operation error occurs, the instruction is not executed,
SM0 is ON, and the error code in SR0 is 16#2003.
Operand
P
S, D
S
T
C
HC
D
Pulse instruction 16-bit instruction (5 steps) 32-bit instruction (5 steps)
AH500
S : Source device
D : Device in which the result is stored
Ch a pt er 6 Ap p l i ed I ns t r uc t i ons
Square root of the binary number
L
SM SR
E
PR
AH500
Function
K
16# "$"
DF
AH500
Word/Double word
Word/Double word
6 - 3 3 9