Additional remark:
1.
If S+2*n-1 used in the instruction ABSD exceeds the device range, the instruction is not
executed, SM0 is ON, and the error code in SR0 is 16#2003.
2.
If S+4*n-1 used in the instruction DABSD exceeds the device range, the instruction is not
executed, SM0 is ON, and the error code in SR0 is 16#2003.
3.
If D+n-1 used in the instruction ABSD exceeds the device range, the instruction is not
executed, SM0 is ON, and the error code in SR0 is 16#2003.
4.
If D+2*n-1 used in the instruction DABSD exceeds the device range, the instruction is not
executed, SM0 is ON, and the error code in SR0 is 16#2003.
5.
If n used in the instruction ABSD is less than 1 or larger than 256, the instruction is not
executed, SM0 is ON, and the error code in SR0 is 16#200B.
6.
If n used in the instruction DABSD is less than 1 or larger than 128, the instruction is not
executed, SM0 is ON, and the error code in SR0 is 16#200B.
Ch a pt er 6 Ap p l i ed I ns t r uc t i ons
6 - 1 6 7