Delta AH500 Programming Manual page 113

Hide thumbs Also See for AH500:
Table of Contents

Advertisement

AH 5 00 Pr ogr am m ing Ma n ua l
Slave 1
Read
Address in
Address in
the master:
the master:
The device
The device
address into
address from
which the
which the
data is read
data is written
(SR1404 and
(SR1468 and
SR1405)
SR1469)
Address in
Address in
the slave:
the slave:
The device
The device
address from
address into
which the
which the
data is read
data is written
(SR1532 and
(SR1596 and
SR1533)
SR1597)
Number of
Number of
data which is
data which is
read from the
written into
slave
the slave
(SR1660)
(SR1692)
Device type
Device type
(SR1340)
(SR1372)
Type of slave 1 (SR1724)
Address of slave 1 (SR1756)
PLC Link flag (SM1392)
Data exchange flag (SM1424)
Read error
Write error
flag
flag
(SM1456)
(SM1488)
The data reading is complete.
(ON->OFF) (SM1520)
The data writing in the PLC
Link is complete. (ON->OFF)
(SM1552)
Please refer to section 11.1 in AH500 Operation Manual for more information related to the
PLC Link.
17. The functions related to the Ether Link
Starting the Ether Link
Port
OFF: Stop
ON: Start
CPU
SM1770
Port 0
SM1772
Port 1
SM1773
Port 2
SM1774
Port 3
SM1775
Port 4
SM1776
Port 5
SM1777
Port 6
SM1778
Port 7
SM1779
Port 8
SM1780
Port 9
SM1781
2 - 9 4
Master
Slave 2
Write
Read
Address in
the master:
The device
address into
which the
data is read
(SR1406 and
SR1407)
Address in
the slave:
The device
address from
which the
data is read
(SR1534 and
SR1535)
Number of
data which is
read from the
slave
(SR1661)
Device type
(SR1341)
Type of slave 2 (SR1725)
Address of slave 2 (SR1757)
PLC Link flag (SM1393)
Data exchange flag (SM1425)
Read error
flag
(SM1457)
The data reading is complete.
(ON->OFF) (SM1521)
The data writing in the PLC
Link is complete. (ON->OFF)
(SM1553)
Ether Link error flag
OFF: Incorrect
ON: Correct
SM1788
SM1790
SM1791
SM1792
SM1793
SM1794
SM1795
SM1796
SM1797
SM1798
SM1799
...
Write
...
Read
Address in
Address in
the master:
the master:
The device
The device
address from
address into
...
which the
which the
data is written
data is read
(SR1470 and
(SR1466 and
SR1471)
SR1467)
Address in
Address in
the slave:
the slave:
The device
The device
address into
address from
...
which the
which the
data is written
data is read
(SR1598 and
(SR1594 and
SR1599)
SR1595)
Number of
Number of
data which is
data which is
written into
...
read from the
the slave
slave
(SR1693)
(SR1691)
Device type
Device type
...
(SR1373)
(SR1371)
...
Type of slave 32 (SR1755)
...
Address of slave 32 (SR1787)
...
PLC Link flag (SM1423)
Data exchange flag (SM1455)
...
Write error
Read error
...
flag
flag
(SM1489)
(SM1487)
The data reading is complete.
...
(ON->OFF) (SM1551)
The data writing in the PLC
...
Link is complete. (ON->OFF)
(SM1583)
Status of the Ether Link
Slave 32
Write
Address in
the master:
The device
address from
which the
data is written
(SR1530 and
SR1531)
Address in
the slave:
The device
address into
which the
data is written
(SR1658 and
SR1659)
Number of
data which is
written into
the slave
(SR1723)
Device type
(SR1340)
Write error
flag
(SM1519)
OFF: Stop
ON: Run
SM1806
SM1808
SM1809
SM1810
SM1811
SM1812
SM1813
SM1814
SM1815
SM1816
SM1817