Preparation For Removal; Removal Of The Ignition System - Rotax 125 MAX evo Repair Manual

Table of Contents

Advertisement

Safety
instructions
Always allow the engine to cool down to ambient temperature before starting any work.

REMOVAL OF THE IGNITION SYSTEM

Safety
instructions
N N O O T T E E
When disconnecting the battery be sure to always disconnect the negative termi-
nal before the positive terminal. Remember that when the engine is running the
ignition system has a high voltage of 35 kV; the spark plug therefore must not be
removed with the engine running.
Instruction
Proceed as follows to disconnect battery. See
1. Remove the Allen screw with rounded flange head M6x20 (3) with O-ring 5x2 (2).
2. Remove the battery cover (1).
3. Disconnect the negative battery terminal (5).
Effectivity: 125 MAX evo, Junior MAX
evo, Mini MAX evo, Micro MAX evo
Edition - February 01 2018 /Rev. 0
BRP-Rotax
REPAIR MANUAL

PREPARATION FOR REMOVAL

Danger of severe burns and scalds!
Ignition "OFF" and system grounded! Disconnect negative terminal of battery.
m WARNING
m WARNING
Risk of electric shock!
Figure:
Battery.
Chapter 3
Page 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

125 junior max evo125 mini max evo125 micro max evo

Table of Contents