2) Preparation

Safety
instructions
NOTES:
The following special tools and equipment are required:
Special tools
Part no. 251680
2.1)

Dismantling the exhaust system

See
Instructions
Proceed as follows to dismantle the exhaust system:
Step
1
2
Effectivity: 125 MAX/125 Junior MAX/125 Mini
MAX/125 Micro MAX
Edition 2 / Rev. 0
BRP-Powertrain
REPAIR MANUAL
Danger of serious burns and scalding!
WARNING
WARNING
Allow engine to cool to ambient temperature before
starting work.
Danger of electric shock!
WARNING
WARNING
Switch off ignition and remove the ignition key. Dis-
connect the negative battery terminal.
When disconnecting the battery leads proceed as follows
- first disconnect the negative pole, then the positive pole.
Remember that the ignition unit is under high voltage
(35 kV) during operation, therefore removal of the spark
plug lead during operation is not permissible.
Part number
Spring hook
Figure 2.
Disconnect tension springs (1) with spring hooks (part no. 251680).
Loosen the nuts (2) on the shock mountings and remove the exhaust system.
Description
Tension spring
Procedure
Use
Chapter 3
Page 5