Magnetizing Curve Flux 3; Magnetizing Curve Flux 4; Magnetizing Curve Imag 1; Magnetizing Curve Imag 2/3 - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 01/06
P0364[3]

Magnetizing curve flux 3

CStat:
CUT
P-Group: MOTOR
Specifies third flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).
Index:
P0364[0] : 1st. Drive data set (DDS)
P0364[1] : 2nd. Drive data set (DDS)
P0364[2] : 3rd. Drive data set (DDS)
Details:
See P0362 (magnetizing curve flux 1).
P0365[3]

Magnetizing curve flux 4

CStat:
CUT
P-Group: MOTOR
Specifies fourth flux value of saturation characteristic in [%] relative to rated motor voltage (P0304).
Index:
P0365[0] : 1st. Drive data set (DDS)
P0365[1] : 2nd. Drive data set (DDS)
P0365[2] : 3rd. Drive data set (DDS)
Details:
See P0362 (magnetizing curve flux 1).
P0366[3]

Magnetizing curve imag 1

CStat:
CUT
P-Group: MOTOR
Specifies first magnetizing current value of the saturation characteristic in [%] relative to the rated
magnetizing current (P0331).
Index:
P0366[0] : 1st. Drive data set (DDS)
P0366[1] : 2nd. Drive data set (DDS)
P0366[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
P0367[3]
Magnetizing curve imag 2
CStat:
CUT
P-Group: MOTOR
Specifies second magnetizing current value of saturation characteristic in [%] relative to rated magnetizing
current (P0331).
Index:
P0367[0] : 1st. Drive data set (DDS)
P0367[1] : 2nd. Drive data set (DDS)
P0367[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
P0368[3]
Magnetizing curve imag 3
CStat:
CUT
P-Group: MOTOR
Specifies third magnetizing current value of saturation characteristic in [%] relative to rated magnetizing
current (P0331).
Index:
P0368[0] : 1st. Drive data set (DDS)
P0368[1] : 2nd. Drive data set (DDS)
P0368[2] : 3rd. Drive data set (DDS)
Dependency:
Affects P0320 (motor magnetizing current).
Details:
See P0362 (magnetizing curve flux 1).
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Datatype: Float
Unit: %
Active: Immediately
QuickComm.: No
Parameter Description
Level
Min:
0.0
4
Def:
115.0
Max:
300.0
Level
Min:
0.0
4
Def:
125.0
Max:
300.0
Level
Min:
0.0
4
Def:
50.0
Max:
500.0
Level
Min:
0.0
4
Def:
75.0
Max:
500.0
Level
Min:
0.0
4
Def:
135.0
Max:
500.0
63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents