Issue 01/06
r0968

Status word 1

P-Group: COMM
Displays active status word of inverter (in binary) and can be used to diagnose which commands are active.
Bitfields:
Bit00
Drive ready
Bit01
Drive ready to run
Bit02
Drive running
Bit03
Drive fault active
Bit04
OFF2 active
Bit05
OFF3 active
Bit06
ON inhibit active
Bit07
Drive warning active
Bit08
Deviation setpoint / act. value
Bit09
PZD control
Bit10
Maximum frequency reached
Bit11
Warning: Motor current limit
Bit12
Motor holding brake active
Bit13
Motor overload
Bit14
Motor runs right
Bit15
Inverter overload
P0970

Factory reset

CStat:
C
P-Group: PAR_RESET
P0970 = 1 resets all parameters to their default values.
Possible Settings:
0
Disabled
1
Parameter reset
Dependency:
-
First set P0010 = 30 (factory settings).
-
Stop drive (i.e. disable all pulses) before you can reset parameters to default values.
Note:
The following parameters retain their values after a factory reset:
-
P0014 Store mode
-
r0039 CO: Energy consumption meter [kWh]
-
P0100 Europe / North America
-
P0918 CB address
-
P2010 USS baud rate
-
P2011 USS address
P0971

Transfer data from RAM to EEPROM

CStat:
CUT
P-Group: COMM
Transfers values from RAM to EEPROM when set to 1.
Possible Settings:
0
Disabled
1
Start transfer
Note:
All values in RAM are transferred to EEPROM.
Parameter is automatically reset to 0 (default) after successful transfer.
The storage from RAM to EEPROM is accomplished via P0971. The communications are reset, if the
transfer was successful. During the reset process communications will be interrupted. This creates the
following conditions:
-
PLC (e.g. SIMATIC S7) enters Stop mode
-
Starter automatically recovers communications once they are re-established.
-
Drivemonitor is displayed "NC" (not connected) in the status line or "drive busy".
-
BOP displays "busy"
After completion of the transfer process, the communication between the inverter and the PC-tools (e.g.
Starter) or BOP is automatically re-established.
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Datatype: U16
Unit: -
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Parameter Description
Min:
-
Def:
-
Max:
-
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
NO
1
YES
0
YES
1
NO
0
YES
1
NO
0
NO
1
YES
0
NO
1
YES
0
YES
1
NO
0
NO
1
YES
0
NO
1
YES
0
YES
1
NO
0
NO
1
YES
0
YES
1
NO
0
NO
1
YES
0
YES
1
NO
Min:
0
Def:
0
Max:
1
Min:
0
Def:
0
Max:
1
Level
3
Level
1
Level
3
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents