Dc Braking Current; Duration Of Dc Braking - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Parameter Description
P1232[3]

DC braking current

CStat:
CUT
P-Group: FUNC
Defines level of DC current in [%] relative to rated motor current (P0305).
r0027
DC
Brake
The current of the DC-braking is limited by r0067.
Index:
P1232[0] : 1st. Drive data set (DDS)
P1232[1] : 2nd. Drive data set (DDS)
P1232[2] : 3rd. Drive data set (DDS)
P1233[3]

Duration of DC braking

CStat:
CUT
P-Group: FUNC
Defines duration for which DC injection braking is to be active following an OFF1 or OFF3 command. When
an OFF1 or OFF3 command is received by the drive, the output frequency starts to ramp to 0 Hz. When the
output frequency reaches the value set in P1234, the drive injects a DC braking current P1232 for the time
duration set in P1233.
1
ON
OFF1/OFF3
OFF2
 f
P1234
DC braking active
r0053
Bit00
2
ON
OFF1/OFF3
OFF2
 f
P1234
DC braking active
r0053
Bit00
The DC current, that is impressed during time P1233, is specified by parameter P1232.
144
Datatype: U16
Active: Immediately
1
P1232
[A]
P0305
100
%
2
Datatype: Float
Active: Immediately
1
0
OFF ramp
1
0
Unit: %
QuickComm.: No
Unit: s
QuickComm.: No
P0347
OFF2
DC braking
P1233
P0347
OFF2
DC braking
OFF2
P1233
MICROMASTER 440
Issue 01/06
Level
Min:
0
2
Def:
100
Max:
250
Level
Min:
0.00
2
Def:
0.00
Max:
250.00