Motor Holding Brake; Holding Brake Enable - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 01/06
3.24

Motor holding brake

P1215

Holding brake enable

CStat:
T
P-Group: FUNC
Enables/disables holding brake function. This function applies the following profile to the inverter:
ON / / / / OFF
ON
OFF1 1 1 1 / / / / OFF
OFF3 3 3 3 : : : :
ON
ON
OFF
OFF
OFF
OFF
OFF1/OFF3
Motor excitation
finished
r0056 Bit04
fmin
(p1080)
r0052.C Bit 12
Brake
Status
closed
ON / / / / OFF
ON
ON
ON
OFF2 2 2 2 : : : :
OFF
OFF
Inactive
OFF2
Active
OFF1/OFF3
Motor excitation
finished
r0056 Bit04
fmin
(p1080)
r0052.C Bit 12
open
Brake
Status
closed
Possible Settings:
0
Motor holding brake disabled
1
Motor holding brake enabled
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Datatype: U16
Active: first confirm
ON
p0346
f
p1216
1
0
open
Brake Release Time
ON
p0346
f
p1216
1
0
Brake Release Time
Parameter Description
Min:
0
Unit: -
Def:
0
QuickComm.: No
Max:
1
p1217
Brake Closing Time
Brake Closing Time
Level
2
t
t
t
t
t
t