Parameter Description

Dependency:

The parameters are sub-divided into groups (P-Group) according to their functionality. This increases the
transparency and allows a parameter to be quickly searched for. Furthermore, parameter P0004 can be
used to control the ability to be visualized for the operator panel.
Value
P-Group
0
ALWAYS
2
INVERTER
3
MOTOR
4
ENCODER
5
TECH_APL
7
COMMANDS
8
TERMINAL
10
SETPOINT
12
FUNC
13
CONTROL
20
COMM
21
ALARMS
22
TECH
Parameters marked "Quick Comm: Yes" in the parameter header can only be set when P0010 = 1 (Quick
Commissioning).
P0005[3]

Display selection

CStat:
CUT
P-Group: FUNC
Selects display for parameter r0000 (drive display).
Index:
P0005[0] : 1st. Drive data set (DDS)
P0005[1] : 2nd. Drive data set (DDS)
P0005[2] : 3rd. Drive data set (DDS)
Common Settings:
21 Actual frequency
25 Output voltage
26 DC link voltage
27 Output current
Notice:
These settings refer to read only parameter numbers ("rxxxx").
Details:
See relevant "rxxxx" parameter descriptions.
P0006

Display mode

CStat:
CUT
P-Group: FUNC
Defines mode of display for r0000 (drive display).
Possible Settings:
0
In Ready state alternate between setpoint and output frequency. In run display output frequency
1
In Ready state display setpoint. In run display output frequency.
2
In Ready state alternate between P0005 value and r0020 value. In run display P0005 value
3
In Ready state alternate between r0002 value and r0020 value. In run display r0002 value
4
In all states just display P0005
Note:
-
When inverter is not running, the display alternates between the values for "Not Running" and
"Running".
-
Per default, the setpoint and actual frequency values are displayed alternately.
P0007

Backlight delay time

CStat:
CUT
P-Group: FUNC
Defines time period after which the backlight display turns off if no operator keys have been pressed.
Value:
P0007 = 0:
Backlight always on (default state).
P0007 = 1 - 2000:
Number of seconds after which the backlight will turn off.
26
Group
All parameters
Drive inverter parameters
Motor parameters
Speed encoder
Technical applications / units
Control commands, digital I/O
Analog inputs/outputs
Setpoint channel and ramp-function gen.
Drive inverter functions
Motor open-loop/closed-loop control
Communications
Faults, warnings, monitoring functions
Technological controller (PID controller)
Datatype: U16
Active: first confirm
Datatype: U16
Active: first confirm
Datatype: U16
Active: first confirm
Parameter area
0200 .... 0299
0300 ... 0399 + 0600 .... 0699
0400 .... 0499
0500 .... 0599
0700 .... 0749 + 0800 ... 0899
0750 .... 0799
1000 .... 1199
1200 .... 1299
1300 .... 1799
2000 .... 2099
2100 .... 2199
2200 .... 2399
Min:
2
Unit: -
Def:
21
QuickComm.: No
Max:
4000
Min:
0
Unit: -
Def:
2
QuickComm.: No
Max:
4
Min:
0
Unit: -
Def:
0
QuickComm.: No
Max:
2000
MICROMASTER 440
6SE6400-5BB00-0BP0
Issue 01/06
Level
2
Level
3
Level
3