Jog Frequency Right; Jog Frequency Left - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 01/06
P1058[3]

JOG frequency right

CStat:
CUT
P-Group: SETPOINT
Jogging increases the motor frequency by small amounts. The JOG buttons uses a non-latching switch on
one of the digital inputs to control the motor frequency.
If JOG clockwise (jogging clockwise) or JOG counter-clockwise is selected, the speed is increased until the
value, set in P1058 is reached.
DIN
BOP
USS
BOP link
USS
COM link
CB
COM link
Index:
P1058[0] : 1st. Drive data set (DDS)
P1058[1] : 2nd. Drive data set (DDS)
P1058[2] : 3rd. Drive data set (DDS)
Dependency:
P1060 and P1061 set up and down ramp times respectively for jogging.
P1059[3]

JOG frequency left

CStat:
CUT
P-Group: SETPOINT
While JOG left is selected, this parameter determines the frequency at which the inverter will run.
Index:
P1059[0] : 1st. Drive data set (DDS)
P1059[1] : 2nd. Drive data set (DDS)
P1059[2] : 3rd. Drive data set (DDS)
Dependency:
P1060 and P1061 set up and down ramp times respectively for jogging.
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Datatype: Float
Active: Immediately
"1"
JOG right
P1055
"0"
(0)
"1"
JOG left
P1056
"0"
(0)
f
P1082
P1058
P1059
-P1082
Datatype: Float
Active: Immediately
Parameter Description
Min:
0.00
Unit: Hz
Def:
5.00
QuickComm.: No
Max:
650.00
A0923
Min:
0.00
Unit: Hz
Def:
5.00
QuickComm.: No
Max:
650.00
Level
2
A0923
t
t
t
Level
2
123