Parameter Description
P2885[2]
CI: CMP 1
CStat:
CUT
P-Group: TECH
Defines inputs of Comparator 1, output is P2886.
P2885
Index 0
Index 1
Index:
P2885[0] : Connector input 0 (CI 0)
P2885[1] : Connector input 1 (CI 1)
Dependency:
P2802[12] is active level for the Comparator.
r2886
BO: CMP 1
P-Group: TECH
Displays result bit of Comparator 1.
Dependency:
P2802[12] is active level for the Comparator.
P2887[2]
CI: CMP 2
CStat:
CUT
P-Group: TECH
Defines inputs of Comparator 2, output is P2888.
Index:
P2887[0] : Connector input 0 (CI 0)
P2887[1] : Connector input 1 (CI 1)
Dependency:
P2802[13] is active level for the Comparator.
r2888
BO: CMP 2
P-Group: TECH
Displays result bit of Comparator 2.
Dependency:
P2802[13] is active level for the Comparator.
P2889
CO: Fixed setpoint 1 in [%]
CStat:
CUT
P-Group: TECH
Fixed percent setting 1.
Connector Setting in %
P2889
P2890
Range : - 200% ... 200 %
P2890
CO: Fixed setpoint 2 in [%]
CStat:
CUT
P-Group: TECH
Fixed percent setting 2.
256
Datatype: U32
Active: first confirm
P2800 P2802[12]
x
1
Out
r2886
x
CMP
2
Out = x1 ≥ x2
Datatype: U16
Datatype: U32
Active: first confirm
Datatype: U16
Datatype: Float
Active: first confirm
Datatype: Float
Active: first confirm
Min:
0:0
Unit: -
Def:
755:0
QuickComm.: No
Max:
4000:0
x1 ≥ x2 → Out = 1
x1 < x2 → Out = 0
Min:
-
Unit: -
Def:
-
Max:
-
Min:
0:0
Unit: -
Def:
755:0
QuickComm.: No
Max:
4000:0
Min:
-
Unit: -
Def:
-
Max:
-
Min:
-200.00
Unit: %
Def:
0.00
QuickComm.: No
Max:
200.00
Min:
-200.00
Unit: %
Def:
0.00
QuickComm.: No
Max:
200.00