Parameter Description
3.16

Setpoint source

P1000[3]

Selection of frequency setpoint

CStat:
CT
P-Group: SETPOINT
Selects frequency setpoint source. In the table of possible settings below, the main setpoint is selected from
the least significant digit (i.e., 0 to 7) and any additional setpoint from the most significant digit (i.e., x0
through to x7).
Possible Settings:
0
No main setpoint
1
MOP setpoint
2
Analog setpoint
3
Fixed frequency
4
USS on BOP link
5
USS on COM link
6
CB on COM link
7
Analog setpoint 2
10
No main setpoint
11
MOP setpoint
12
Analog setpoint
13
Fixed frequency
14
USS on BOP link
15
USS on COM link + MOP setpoint
16
CB on COM link
17
Analog setpoint 2 + MOP setpoint
20
No main setpoint
21
MOP setpoint
22
Analog setpoint
23
Fixed frequency
24
USS on BOP link
25
USS on COM link + Analog setpoint
26
CB on COM link
27
Analog setpoint 2 + Analog setpoint
30
No main setpoint
31
MOP setpoint
32
Analog setpoint
33
Fixed frequency
34
USS on BOP link
35
USS on COM link + Fixed frequency
36
CB on COM link
37
Analog setpoint 2 + Fixed frequency
40
No main setpoint
41
MOP setpoint
42
Analog setpoint
43
Fixed frequency
44
USS on BOP link
45
USS on COM link + USS on BOP link
46
CB on COM link
47
Analog setpoint 2 + USS on BOP link
50
No main setpoint
51
MOP setpoint
52
Analog setpoint
53
Fixed frequency
54
USS on BOP link
55
USS on COM link + USS on COM link
57
Analog setpoint 2 + USS on COM link
60
No main setpoint
61
MOP setpoint
62
Analog setpoint
63
Fixed frequency
64
USS on BOP link
66
CB on COM link
67
Analog setpoint 2 + CB on COM link
70
No main setpoint
71
MOP setpoint
72
Analog setpoint
73
Fixed frequency
74
USS on BOP link
75
USS on COM link + Analog setpoint 2
76
CB on COM link
77
Analog setpoint 2 + Analog setpoint 2
110
Datatype: U16
Active: first confirm
+ MOP setpoint
+ MOP setpoint
+ MOP setpoint
+ MOP setpoint
+ MOP setpoint
+ MOP setpoint
+ Analog setpoint
+ Analog setpoint
+ Analog setpoint
+ Analog setpoint
+ Analog setpoint
+ Analog setpoint
+ Fixed frequency
+ Fixed frequency
+ Fixed frequency
+ Fixed frequency
+ Fixed frequency
+ Fixed frequency
+ USS on BOP link
+ USS on BOP link
+ USS on BOP link
+ USS on BOP link
+ USS on BOP link
+ USS on BOP link
+ USS on COM link
+ USS on COM link
+ USS on COM link
+ USS on COM link
+ USS on COM link
+ CB on COM link
+ CB on COM link
+ CB on COM link
+ CB on COM link
+ CB on COM link
+ CB on COM link
+ Analog setpoint 2
+ Analog setpoint 2
+ Analog setpoint 2
+ Analog setpoint 2
+ Analog setpoint 2
+ Analog setpoint 2
Min:
0
Unit: -
Def:
2
QuickComm.: Yes
Max:
77
MICROMASTER 440
6SE6400-5BB00-0BP0
Issue 01/06
Level
1
Parameter List