No. Of Shaft Turns = 1 Unit; Distance/No. Of Revolutions; Act. Number Of Shaft Revolutions - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Parameter Description
P2484[3]

No. of shaft turns = 1 Unit

CStat:
CUT
P-Group: CONTROL
Sets the number of rotations of the motor shaft required to represent 1 unit of user selected units.
The following equation determines the number of motor shaft revolutions to stop:
Revolutions
Motor
Index:
P2484[0] : 1st. Drive data set (DDS)
P2484[1] : 2nd. Drive data set (DDS)
P2484[2] : 3rd. Drive data set (DDS)
P2488[3]
Distance / No. of revolutions
CStat:
CUT
P-Group: CONTROL
Sets the required distance or number of revolutions (see P2484).
f
f
OFF 1
Index:
P2488[0] : 1st. Drive data set (DDS)
P2488[1] : 2nd. Drive data set (DDS)
P2488[2] : 3rd. Drive data set (DDS)
r2489

Act. number of shaft revolutions

P-Group: CONTROL
Displayes the actual number of shaft revolutions since trigger of positioning.
Note:
Positioning ramp down is an open loop control method. So, there might be a difference between the position
setpoint and the calculated actual position shown in r2489. That means, it could happen that the setpoint
position is already reached, although r2489 displays a different actual position .
240
Datatype: Float
Active: first confirm
Pulley radius r
Load
U
U
No. of revolutions
=
=
P2484
1 [unit]
s
P
2481
=
P
2488
P
2484
P
2482
Datatype: Float
Active: first confirm
Motor
Gear
OFF1
t
P2488
Datatype: Float
Min:
Unit: -
Def:
QuickComm.: No
Max:
Distance s
Min:
Unit: -
Def:
QuickComm.: No
Max:
1
.
.
=
=
s
P2488
f
t
OFF 1
2
t
Min:
Unit: -
Def:
Max:
MICROMASTER 440
Issue 01/06
Level
0.01
3
1.00
9999.99
Level
0.01
3
1.00
9999.99
P2488
Level
-
3
-
-
Parameter List
6SE6400-5BB00-0BP0