P3980 Commissioning Command Selection; P3981 Reset Active Fault; R3986[2] Number Of Parameters - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Parameter Description
P3980
Commissioning command selection
CStat:
T
P-Group: -
Toggles command and setpoint sources between freely programmable BICO parameters and fixed
command/setpoint profiles for commissioning.
The command and setpoint sources can be changed independently. The tens digit selects the command
source, the ones digit the setpoint source.
Possible Settings:
0
Cmd = BICO parameter
1
Cmd = BICO parameter
2
Cmd = BICO parameter
3
Cmd = BICO parameter
4
Cmd = BICO parameter
5
Cmd = BICO parameter
6
Cmd = BICO parameter
7
Cmd = BICO parameter
10
Cmd = BOP
11
Cmd = BOP
12
Cmd = BOP
13
Cmd = BOP
15
Cmd = BOP
16
Cmd = BOP
17
Cmd = BOP
40
Cmd = USS on BOP link
41
Cmd = USS on BOP link
42
Cmd = USS on BOP link
43
Cmd = USS on BOP link
44
Cmd = USS on BOP link
45
Cmd = USS on BOP link
46
Cmd = USS on BOP link
47
Cmd = USS on BOP link
50
Cmd = USS on COM link
51
Cmd = USS on COM link
52
Cmd = USS on COM link
53
Cmd = USS on COM link
54
Cmd = USS on COM link
55
Cmd = USS on COM link
57
Cmd = USS on COM link
60
Cmd = CB on COM link
61
Cmd = CB on COM link
62
Cmd = CB on COM link
63
Cmd = CB on COM link
64
Cmd = CB on COM link
66
Cmd = CB on COM link
67
Cmd = CB on COM link
P3981
Reset active fault
CStat:
CT
P-Group: ALARMS
Resets active faults when changed from 0 to 1.
Possible Settings:
0
No fault reset
1
Reset fault
Note:
Automatically reset to 0.
Details:
See r0947 (last fault code)
r3986[2]
Number of parameters
P-Group: -
Number of parameters on the drive
Index:
r3986[0] : Read only
r3986[1] : Read & write
258
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Setpoint = BICO parameter
Setpoint = MOP setpoint
Setpoint = Analog setpoint
Setpoint = Fixed frequency
Setpoint = USS on BOP link
Setpoint = USS on COM link
Setpoint = CB on COM link
Setpoint = Analog 2 setp
Setpoint = BICO parameter
Setpoint = MOP setpoint
Setpoint = Analog setpoint
Setpoint = Fixed frequency
Setpoint = USS on COM link
Setpoint = CB on COM link
Setpoint = Analog 2 setp
Setpoint = BICO parameter
Setpoint = MOP setpoint
Setpoint = Analog setpoint
Setpoint = Fixed frequency
Setpoint = USS on BOP link
Setpoint = USS on COM link
Setpoint = CB on COM link
Setpoint = Analog 2 setp
Setpoint = BICO parameter
Setpoint = MOP setpoint
Setpoint = Analog setpoint
Setpoint = Fixed frequency
Setpoint = USS on BOP link
Setpoint = USS on COM link
Setpoint = Analog 2 setp
Setpoint = BICO parameter
Setpoint = MOP setpoint
Setpoint = Analog setpoint
Setpoint = Fixed frequency
Setpoint = USS on BOP link
Setpoint = CB on COM link
Setpoint = Analog 2 setp
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Datatype: U16
Unit: -
Issue 01/06
Min:
0
Def:
0
Max:
67
Min:
0
Def:
0
Max:
1
Min:
-
Def:
-
Max:
-
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Level
4
Level
4
Level
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents