ParNo
Parameter text
r0020
CO: Freq. setpoint before RFG
r0021
CO: Act. filtered frequency
r0024
CO: Act. filtered output freq.
r0025
CO: Act. filtered output voltage
r0026
CO: Act. filtered DC-link volt.
r0027
CO: Act. filtered output current
r0029
CO: Flux gen. current
r0030
CO: Torque gen. current
r0031
CO: Act. filtered torque
r0032
CO: Act. filtered power
r0035[3]
CO: Act. motor temperature
r0036
CO:Inverter overload utilization
r0037[5]
CO: Inverter temperature [°C]
r0038
CO: Act. power factor
r0039
CO: Energy consumpt. meter [kWh]
r0050
CO: Active command data set
r0051[2]
CO: Active drive data set (DDS)
r0061
CO: Act. encoder frequency
r0062
CO: Freq. setpoint
r0063
CO: Act. frequency
r0064
CO: Dev. frequency controller
r0065
CO: Slip frequency
r0066
CO: Act. output frequency
r0067
CO: Act. output current limit
r0068
CO: Output current
r0069[6]
CO: Act. phase currents
r0070
CO: Act. DC-link voltage
r0071
CO: Max. output voltage
r0072
CO: Act. output voltage
r0074
CO: Act. modulation
r0075
CO: Current setpoint Isd
r0076
CO: Act. current Isd
r0077
CO: Current setpoint Isq
r0078
CO: Act. current Isq
r0079
CO: Torque setpoint (total)
r0080
CO: Act. torque
r0084
CO: Act. air gap flux
r0086
CO: Act. active current
r0090
CO: Act. rotor angle
r0394
CO: Stator resistance IGBT [%]
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
ParNo
Parameter text
r0395
CO: Total stator resistance [%]
r0396
CO: Act. rotor resistance
r0630[3]
CO: Ambient temperature
r0631[3]
CO: Stator iron temperature
r0632[3]
CO: Stator winding temperature
r0633[3]
CO: Rotor winding temperature
r0755[2]
CO: Act. ADC after scal. [4000h]
r0947[8]
CO: Letzte Fehlermeldung
r0948[12]
CO: Fehlerzeit
r0949[8]
CO: Fehlerwert
r1024
CO: Act. fixed frequency
r1050
CO: Act. Output freq. of the MOP
r1078
CO: Total frequency setpoint
r1079
CO: Selected frequency setpoint
r1114
CO: Freq. setp. after dir. ctrl.
r1119
CO: Freq. setpoint before RFG
r1170
CO: Frequency setpoint after RFG
r1242
CO: Switch-on level of Vdc-max
r1246[3]
CO:Switch-on level kin buffering
r1315
CO: Total boost voltage
r1337
CO: V/f slip frequency
r1343
CO: Imax controller freq. output
r1344
CO: Imax controller volt. output
r1438
CO: Freq. setpoint to controller
r1445
CO: Act. filtered frequency
r1482
CO: Integral output of n-ctrl.
r1490
CO: Droop frequency
r1508
CO: Torque setpoint
r1515
CO: Additional torque setpoint
r1518
CO: Acceleration torque
P1520[3]
CO: Upper torque limit
P1521[3]
CO: Lower torque limit
r1526
CO: Upper torque limitation
r1527
CO: Lower torque limitation
r1536
CO: Max. trq. motoring current
r1537
CO: Max trq regenerative current
r1538
CO: Upper torque limit (total)
r1539
CO: Lower torque limit (total)
P1570[3]
CO: Fixed value flux setpoint
r1583
CO: Flux setpoint (smoothed)