Parameter Description; Common Parameters - Siemens MICROMASTER 440 Parameter Manual

0.12 kw - 250 kw
Hide thumbs Also See for MICROMASTER 440:
Table of Contents

Advertisement

Issue 01/06
3

Parameter Description

Note
Level 4 Parameters are not visible with BOP or AOP.
3.1

Common parameters

r0000
Drive display
P-Group: ALWAYS
Displays the user selected output as defined in P0005.
Note:
Pressing the "Fn" button for 2 seconds allows the user to view the values of DC link voltage, output
frequency, output voltage, output current, and chosen r0000 setting (defined in P0005).
r0002
Drive state
P-Group: COMMANDS
Displays actual drive state.
Possible Settings:
0
Commissioning mode (P0010 != 0)
1
Drive ready
2
Drive fault active
3
Drive starting (DC-link precharging)
4
Drive running
5
Stopping (ramping down)
Dependency:
State 3 visible only while precharging DC link, and when externally powered communications board is fitted.
P0003
User access level
CStat:
CUT
P-Group: ALWAYS
Defines user access level to parameter sets. The default setting (standard) is sufficient for most simple
applications.
Possible Settings:
0
User defined parameter list - see P0013 for details on use
1
Standard: Allows access into most frequently used parameters.
2
Extended: Allows extended access e.g. to inverter I/O functions.
3
Expert: For expert use only.
4
Service: Only for use by authorized service personal - password protected.
P0004
Parameter filter
CStat:
CUT
P-Group: ALWAYS
Filters available parameters according to functionality to enable a more focussed approach to
commissioning.
Possible Settings:
0
All parameters
2
Inverter
3
Motor
4
Speed sensor
5
Technol. application / units
7
Commands, binary I/O
8
ADC and DAC
10
Setpoint channel / RFG
12
Drive features
13
Motor control
20
Communication
21
Alarms / warnings / monitoring
22
Technology controller (e.g. PID)
Example:
P0004 = 22 specifies that only PID parameters will be visible.
MICROMASTER 440
Parameter List
6SE6400-5BB00-0BP0
Datatype: U16
Unit: -
Datatype: U16
Unit: -
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Datatype: U16
Unit: -
Active: first confirm
QuickComm.: No
Parameter Description
Level
Min:
-
1
Def:
-
Max:
-
Level
Min:
-
2
Def:
-
Max:
-
Level
Min:
0
1
Def:
1
Max:
4
Level
Min:
0
1
Def:
0
Max:
22