Note: Each column has a spring-loaded mechanism that pushes a tape cartridge into Tier 1 when it is the
only cartridge in that column. A single cartridge in a column takes on the Tier 2 element address even
though it is physically in Tier 1.
Figure 7. Location coordinates
A storage element address is assigned to each cartridge at the time the cartridge is inserted. Storage
element addresses range from 4097 to 4105 (0x1001 to 0x1009) when the I/O station is not enabled, and
from 4097 to 4104 (0x1001 to 0x1008) when the I/O station is enabled.
Library specifications
Table 7. Physical specifications
Parameter
Front panel width (chassis/bezel)
Depth
Height
Weight (library only)
Table 8. Electrical specifications
Parameter
Voltage
Frequency
Power consumption
For more information about installation specifications, see "Installation and configuration" on page 21.
Table 9. Environmental specifications
Parameter
Temperature
Temperature variation
Relative humidity
Wet bulb temperature
Altitude (meters)
10
IBM TS2900 Tape Autoloader: Setup, Operator, and Service Guide Machine Type 3572
Front
Reserved slot
Column 5
Column 4
Column 3
Tier 2
Tier 2
Tier 2
Column 5
Column 4
Column 3
Tier 1
Tier 1
Tier 1
Operating (see Note)
10 - 38 °C (50 - 100 °F)
10 °C/hour (maximum)
20 - 80%
26 °C (78.8 °F) maximum
0 - 2,500
Column 2
Column 1
Tier 2
Tier 2
Column 2
Column 1
Drive
Tier 1
Tier 1
Accessor
Measurement
445 mm (17.52 in.)/483 mm (19.02 in.)
850 mm (33.46 in.)
44 mm (1.73 in.)
13 kg (28.66 lbs)
Measurement
100 - 240 Vac. (4.0 to 1.5 A)
50 - 60 Hz
Storage
1 - 60 °C (34 - 140 °F)
10 °C/hour (maximum)
10 - 90%
29 °C (84 °F) maximum
0 - 2,500
Rear
110 W
Shipping
-40 to 60 °C (-40 to 140 °F)
10 °C/hour (maximum)
10 - 90%
29 °C (84 °F) maximum
0 - 2,500