Page 3
Tables of Contents Welcome Overview What's new Introduction Components Front panel Rear panel Cartridge magazine Bar code reader User interfaces Supported tape drives Drive features Media optimization Archive mode unthread Speed matching Capacity scaling Channel calibration Power management Supported tape cartridges Library functions Encryption Alerts and logging...
Page 4
Disposing of tape cartridges Ordering media supplies Ordering bar code labels Replacement parts Information for trained IBM service personnel Web User Interface service login Connecting to the library with the Telnet service port Drive or cartridge removal procedure Removing or reinstalling the library chassis cover...
Page 5
Removing a stuck cartridge magazine Message retrieval at the host Obtaining error information from an IBM System p Retrieving from an IBM System i with RISC processor Accessibility Notices Trademarks Terms and conditions for product documentation Homologation statement Electromagnetic compatibility notices...
The library has a compact 1U form factor with easy access to tape cartridges with a removable magazine. It is equipped with a Serial Attached SCSI (SAS) host adapter attachment that has a data transfer rate of up to 12 Gbps. The TS2900 Tape Autoloader is an external stand-alone or rack-mountable unit that incorporates one of...
Serial number The machine type and serial number of the library are on the front bezel of the library. The serial number is the number that links the label library to IBM entitlement for service. 6 Air vents These vents draw cooler air into the library enclosure and allow warm air to escape which helps to keep the library at a normal operating temperature.
Location coordinates and element addresses The library incorporates IBM® patented high-density (HD) slot technology, which allows multiple cartridges to be stored in a tiered architecture. The depth of a cartridge location in a high-density slot is known as a tier. High-density slots are designed to contain multiple cartridges in Tiers 1 and 2.
This approach helps to reduce the number of backhitch repositions and improves throughput performance. Capacity scaling You can control the capacity of data cartridges to obtain faster seek time. Channel calibration System performance is optimized by channel calibration. Power management TS2900 Tape Autoloader 5...
Capacity scaling You can control the capacity of data cartridges to obtain faster seek time. To control the capacity of the cartridge, issue the SCSI command SET CAPACITY. For more information, see IBM LTO Ultrium Tape Drive SCSI Reference. Channel calibration...
4. The library Firmware must be at 0080 or greater and drive firmware must be at HB82 or greater to support the LTO M8 media feature. To know more about Ultrium M8 tape cartridges, see LTO type M cartridge (M8). For more information, see media. Library functions The library provides many specific functions, such as alerts and logging, random and sequential logical library modes, and encryption. TS2900 Tape Autoloader 7...
The new configuration capability of SNMP Query provides a common Management Information Base (MIB) across all the IBM tape libraries. This capability allows a product administrator to audit the settings of all their IBM tape libraries to ensure that they comply with their own policies.
Unless otherwise stated by product-specific installation instructions. Note: Condensation is a normal occurrence, especially when you ship equipment in cold-weather climates. All IBM® products are tested and verified to withstand condensation that is produced under these circumstances. When sufficient time is provided to allow the hardware to gradually acclimate to the indoor environment, there should be no issues with long-term reliability of the product.
Page 15
You are responsible for the security of this library, the cartridges that are contained within the library, and shelf-resident cartridges. To prevent unauthorized access to data, IBM recommends locating the library and all shelf-resident cartridges in an area where access is controlled.
For data centers with airside economizers, the choice of filters to achieve ISO class 8 cleanliness depends on the specific conditions present at that data center. The deliquescent relative humidity of the particulate contamination should be more than 60% RH.3 .Data centers must be free of zinc whiskers TS2900 Tape Autoloader 11...
1. Match the index number that is beside each plug to the index number in the table. Figure 1. Types of power cord receptacles Table 1. Power cords Description, Feature Code Plug Standard Index Number Country or Region (FC), and Part Reference Figure 1 Number (PN) 12 TS2900 Tape Autoloader...
Page 18
Denmark 2.8 m, 250V FC 9821 AAS PN 39M5130 HVEC/SA P PN 23R7147 South Africa SABS 164 Bangladesh, Burma, Pakistan, South Africa, Sri Lanka 2.8 m, 250V FC 9829 AAS PN 39M5144 HVEC/SA P PN 23R7151 TS2900 Tape Autoloader 13...
Page 19
23R7154 China CCEE People's Republic of China 2.8 m, 250V FC 9840 AAS PN 39M5206 HVEC/SA P PN 23R7155 Taiwan LV* CNS 10917-3 Taiwan 2.8 m, 125V FC 9835 AAS PN 39M5247 HVEC/SA P PN 23R7158 14 TS2900 Tape Autoloader...
Page 20
Brazil LV* InMetro NBR Brazil 6147 2.8 m, 125V FC 9846 AAS PN 39M5233 HVEC/SA P PN 23R6986 Brazil HV** InMetro NBR Brazil 14136 2.8 m, 250V FC 9847 AAS PN 39M5240 HVEC/SA P PN 23R6987 TS2900 Tape Autoloader 15...
Supported browsers IBM® supports higher versions of the browsers if the vendors do not remove or disable functions that the product relies upon. For browser levels higher than the versions that are certified with the product, customer support accepts usage-related and defect-related service requests. As with operating system and virtualization environments, if IBM support cannot re-create the issue in the lab, the client might be asked to re-create the problem on a certified browser version to determine whether...
2. IBM® does not provide application software with the drive. To order software, contact your IBM sales representative, IBM Business Partner, or an independent software provider. 3. If you attach your drive to a server with non-IBM software, contact your software vendor for a matrix of compatible hardware, software, firmware revisions, and adapters.
Use the packing slip that is included with your library to identify the library components. The TS2900 model 3572 is not shipped with the rack mount kit (IBM FC: 7006) and/or power cord (IBM FC: 9800-9847) unless it is ordered.
Page 24
Figure 3. Attaching the cover to the library chassis (side screws) 5. Attach the deskside cover with the two large binding-head screws 4 on the rear of the library (Figure Figure 4. Attaching the cover to the library chassis (rear screws) TS2900 Tape Autoloader 19...
Installing in a rack The TS2900 Tape Autoloader can be easily installed into a standard 19-inch rack system. A standard 19-inch rack system contains multiple mounting locations that are called EIA units as defined by the Electronics Industries Association. Each EIA unit contains three square or round holes that are used to mount rack designed equipment.
Page 26
3) front brackets to the front of the library chassis with 2 flat-head screws 8 on each side. Use the bottom two screw holes on each side. Figure 3. Attaching the front brackets to the library chassis TS2900 Tape Autoloader 21...
Page 27
4 flat-head screws 9 on each side of the rack. Use both of the two screw locations on the rear of the rack rail (Figure 2). Use the top and middle screw locations on the front of the rack rail (Figure Figure 6. Installing the rail assemblies 22 TS2900 Tape Autoloader...
Page 28
9. Run the SAS cable, power cable, and Ethernet cable through the hook-and-loop fastener strap 12 . Leave enough slack to reach the corresponding connectors, then tighten the strap (Figure Figure 9. The cables at the rear of the library Note: For information about converting and relocating the library, see Upgrading and servicing. TS2900 Tape Autoloader 23...
Note: On rack mount installations, run the rack PDU power cord through the hook-and-loop fastener strap on the right rear bracket, and tighten the strap. The rack PDU power cord is a special power cord that plugs into a rack power strip. 24 TS2900 Tape Autoloader...
Before the library can be managed over a network with the Web User Interface, set up the initial network configuration of the library with the Operator Panel. For information, see Configuring network settings. To log in to the Web User Interface: TS2900 Tape Autoloader 25...
Note: Do not rely on the bar code label orientation, if attached, to provide an indication of the correct cartridge orientation. The bar code label is right side up if attached correctly. Figure 3. Cartridge orientation 26 TS2900 Tape Autoloader...
1. Install the application software and drivers that are compatible with the library. Backup software packages might require extra software or licensing to communicate with the robotics. 2. Verify the connection between the library and the host by using the host server’s operating system utilities. Or, use the IBM® Tape Diagnostic Tool (ITDT) to verify the communication between library and host. See IBM Tape Diagnostic tool (ITDT).
For more information about initial logging in to the Web User Interface, see Logging in to the Web User Interface. The Library main screen on the Web User Interface Figure 1 shows the Web User Interface window for an Administrator account. Figure 1. Administrator account window 28 TS2900 Tape Autoloader...
Page 34
Library Map Unload Drive User Access Key Path Diagnostics Clean Drive Physical/Logical View Library Logs Library State Network Download Logs Inventory Encryption Reset Library/Drive Unlock Magazine Date and Time Firmware Update SMTP Usage Statistics SNMP Certificate Save/Restore TS2900 Tape Autoloader 29...
Page 35
Library mode (Random or Sequential). In Sequential mode, Loop and Auto load mode are also displayed. Bar code label length 2 Ethernet Displays the following information: Ethernet Information TCP/IP Settings IPv4/IPv6 Settings SMTP Settings SNMP Settings 30 TS2900 Tape Autoloader...
Managing user access Users that can access the library are added, modified, or removed by using the Web User Interface. Up to seven users can be configured with the Web User Interface. Figure 1. User Access screen TS2900 Tape Autoloader 31...
Page 37
Superuser - Superuser access permission allows users to operate the physical and logical library, but not to change configuration settings. Administrator - Administrator access permission allows users to complete tape library functions and change configuration settings. 32 TS2900 Tape Autoloader...
Bar code label length - Use to choose the number of characters in the cartridge bar code that is reported to the host computer. 3. Click Submit to enable the settings. Logical library settings Figure 2. Logical library mode settings TS2900 Tape Autoloader 33...
After the network settings are entered on the Operator Panel, the current network configuration of the library can be modified with the Web User Interface. The changes that are made to the network settings take effect after the library is rebooted. Figure 1. Network settings screen 34 TS2900 Tape Autoloader...
Note: The Internet Protocol (IPv4, IPv6, or dual IPv4/IPv6) selection is used for the TS2900 Tape Autoloader IP address, subnet mask, gateway address, time server address, mail server address, SNMP trap address, and EKM server addresses. To modify the network settings, follow the procedure: 1.
Page 41
Internal Label - Encrypt All - This option is used only for Veritas Technologies NetBackup. 8. Skip over the Advanced Encryption Settings. The purpose of these advanced encryption settings is to allow only IBM Support personnel (under the direction of the drive development team) to provide a solution to an unforeseen problem or to support a unique configuration.
Click Load PC date time to synchronize the library with the clock on your host computer at regular intervals. 3. Click Submit to update the settings. Configuring email notifications Email notifications can be configured to notify you when a library event takes place. Figure 1. Email notifications TS2900 Tape Autoloader 37...
4. Select the event level to report in the Mail Event settings. 5. Click Test to send a test email message to the enabled addresses. 6. Click Submit to enable the settings. Configuring SNMP notifications SNMP notifications can be configured for this library. Figure 1. Trap notifications 38 TS2900 Tape Autoloader...
7. Select the event level to report in the Trap Event box. 8. Click Test to send a test trap notification to the enabled IP addresses. 9. Click Submit to enable the settings. Uploading and configuring the SSL certificate TS2900 Tape Autoloader 39...
Note: When a user-provided certificate and private key are removed, the system defaults to the self-signed certificate and private key that shipped with the machine. Note: The imported SSL Certificate/Private Key is not saved during the Save/Restore function on the Autoloader. If the IBM TS2900 Autoloader is replaced, the SSL Certificate and the Private Key must be imported again, if needed.
16-character LCD graphic display 2 Plus key (+) Button that is used to navigate upward (↑) through the menu items. 3 Minus key (-) Button that is used to navigate downward (↓) through the menu items. TS2900 Tape Autoloader 41...
LCD screen to help identify the reason of failure. Table 3. Front Panel Indicators Message on the LCD Library Condition Ready/Activity LED Cleaning LED Attention LED Error LED screen POST (Power ON Self Test) Flashes 2 times every 3 INITIALIZING... seconds INVENTORY... 42 TS2900 Tape Autoloader...
Page 48
1. From the top menu screen, press the Minus key to select Configuration, and press Enter. 2. Select Configure Library, and press Enter. 3. Active Slots (Default: All) a. Select Configure Library > Set Active Slots Count. TS2900 Tape Autoloader 43...
Page 49
Panel, complete this procedure. Figure 1. Network settings 1. From the top menu screen, press the Minus key to select Configuration, and press Enter. 2. Link speed (Default: Auto Negotiation) a. Select Configure Network Settings > Configure Link Speed. 44 TS2900 Tape Autoloader...
Configure Library > Physical/Logical > Physical Settings. See Methods Configuration > Configure Auto Cleaning. See Methods of cleaning the of cleaning the tape drive. tape drive. Not available with this interface Configuration > Set Default Reset configuration TS2900 Tape Autoloader 45...
Page 51
Update drive firmware Service Library > Firmware Update. See Updating library and drive Not available with this interface firmware. * The drive status may display Failed until the drive is back online. Table 5. Managing cartridges 46 TS2900 Tape Autoloader...
DNS IP address 0.0.0.0 PHYSICAL Library name (Blank) Auto Cleaning Disabled Bar code label length 8 characters LOGICAL Library mode Random Loop Enabled Auto Load Enabled Active slots 9 + 0 ENCRYPTION (S4H and LATER ONLY) TS2900 Tape Autoloader 47...
2. Use Service Library > Firmware Update and click Browse to locate the library firmware file with extension ".fmg" (for example, TS2900_0002.0000.fmg) or the LTO SAS drive firmware file with extension".ro" (for example, 85F0L3AH.ro) that you downloaded from the IBM web site, then click Update.
The head of the tape drive in the tape library must be kept clean to prevent errors that are caused by contamination. To help you keep the drive clean, IBM provides a cleaning cartridge with the library. The library uses the cleaning cartridge to clean the drive with whatever cleaning method that you choose. In all methods, cleaning is done after the data cartridge is unloaded from the drive and before the next load.
The type of event that generates email notification or SNMP trap notification can be selected to limit the number of events to a specific priority level. Customers can frequently resolve a simple problem themselves by with the information found in Troubleshooting guide. If the problem is unrecoverable, the customer must contact IBM® Technical Support, see Contacting IBM technical support. Running library tests The library provides the following tests to verify library operations.
Page 56
Refer to the following tables that list the errors or symptoms that might occur with the TS2900 Tape Autoloader. The tables provide action to correct the problems.If replacement parts are needed, go to Replacement parts. See Contacting IBM technical support.
Page 57
Cartridge care and handling for instructions about handling the media. It is possible that your other cartridges might also be damaged. If your cartridge does not eject properly, contact your service representative.IBM service personnel must go to Information for trained IBM service personnel.
Page 58
If ITDT cannot locate the LTO drive successfully, suspect cabling or HBA problems, and skip to Step 4. b. If ITDT located the LTO drive successfully, proceed to Step 3. See IBM Tape Diagnostic tool (ITDT) for a brief description of ITDT and instructions on how to download the tool from the web.
Pre-call checklist If you have questions or problems with the library, complete these steps before a call to IBM technical support is placed. Note: Where instructions refer you to the web, go to http://www.ibm.com/storage/support/lto. 1. Verify that you exhausted all troubleshooting options. See Troubleshooting guide.
The IBM Support Center assists with problem determination and can initiate shipment of a replacement part, if needed, to the customer’s location. Transportation costs, both ways, are paid by IBM. The replacement part becomes the property of the customer in exchange for the failed part, which becomes the property of IBM.
The IBM Tape Diagnostic Tool (ITDT) is a command-line utility. Start it by entering the executable command from the directory where the tool is located. The Help feature gives a brief explanation of each function and shows the required syntax.
Page 62
Transfer Ready IU event timeout detected. 002F LDI I/F error. Undefined error detected. 0040 A drive media error detected upon insertion. CHK 0040 1. Verify that the cartridge is compatible with the drive in your library. See Table TS2900 Tape Autoloader 57...
Page 63
GET, centering check, or bar code reader CHK 0074 read operation failed because the accessor contains media. Suspect the centering sensor. 0075 PUT operation failed because the accessor CHK 0075 contains no media. Suspect the centering sensor. 58 TS2900 Tape Autoloader...
Page 64
2. Cycle the power supply and try again. completion of PUT operation. Suspect the If the problem is corrected, run Library Verify before normal library centering sensor. operations resume. See Running library verify test. If the problem persists, see Contacting IBM technical support. TS2900 Tape Autoloader 59...
Page 65
If the problem persists, see Contacting IBM technical support. memory. 00E2 Error detected in tape library configuration CHK 00E2 stored in flash memory. 00E3 Checksum error detected in flash memory. CHK 00E3 60 TS2900 Tape Autoloader...
Invalid parameter found in [***]. Configure Library Please input parameter of [***]. Configure Library Password parameter error. User Access User name parameter error. User Access Not enough role. User Access A user name unmatched. User Access TS2900 Tape Autoloader 61...
Trap definitions (types) The library supports the following types of SNMP traps. Table 1. Trap list Trap ID Event Type Description Clean Drive LED Attention LED Error LED Emergency Drive error Library error Error Drive error Library error 62 TS2900 Tape Autoloader...
2. Restart the operation. 3. If the problem persists, see Contacting IBM technical support. Library Library preventive maintenance Preventive maintenance of the library is required. Consult the library user's Maintenance required. manual for device-specific preventive maintenance tasks. TS2900 Tape Autoloader 63...
Do not attempt to extract the tape cartridge. See Contacting IBM snapped tape drive snapped. technical support. Cartridge Set when a cartridge memory (CM) failure is detected on Replace the tape cartridge. memory chip the loaded tape cartridge. failure 64 TS2900 Tape Autoloader...
Page 70
If damaged, discard it. 3. Try to unload the cartridge from the drive again with the Web User Interface or Operator Panel. 4. If the cartridge still does not unload from the drive, see Contacting IBM technical support. TS2900 Tape Autoloader 65...
IBM LTO Ultrium Tape Drive SCSI Reference for tape drive sense data information. In addition, you can use the IBM Tape Diagnostic Tool (ITDT) to further examine data and determine errors. See IBM Tape Diagnostic tool (ITDT) for more information.
Figure 1. Insert accessor locking screw 9. Remove the SAS cable, power cable, and Ethernet cable from the hook-and-loop fastener strap 12 on the rear of the library (Figure Figure 2. Removing cables at the rear of the library TS2900 Tape Autoloader 67...
Page 73
For details on the deskside kit components, see Installing on a tabletop. 1. Attach the left 5 and right 3 rails to the chassis with 3 flat-head screws 6 on each side (Figure Figure 6. Attaching the side rails to the library chassis 68 TS2900 Tape Autoloader...
Page 74
Connect the power cable from the library power supply. Route all cables through the hook-and-loop fastener strap. d. Power ON the library by toggling the power supply switch to the ON (|) position. 8. Insert the cartridge magazine if previously removed. TS2900 Tape Autoloader 69...
Figure 3. Removing the cover from the library chassis 11. Turn the library over and remove the feet 1 from the bottom of the library (Figure 4). Return the library to the upright position. Figure 4. Removing the feet 70 TS2900 Tape Autoloader...
Figure 7. Attaching the rear brackets to the rails 4. Slide in the rear rails 7 from back to front to create the rail assemblies. Ensure that the screw holes face outwards (Figure Figure 8. Attaching the rear brackets to the rails TS2900 Tape Autoloader 71...
Page 77
7. Secure the rear of the library to the rack with 2 round-head screws 10 on each rear bracket (Figure 11). Tighten the other rear bracket screws to secure the library to the rack. Figure 11. Securing the rear of the library in the rack 72 TS2900 Tape Autoloader...
The entire library, including the drive, is a Customer Replaceable Unit (CRU). At CRU replacement, the serial number of the new library must be changed to the serial number of the old library to maintain IBM® entitlement to service. If the static IP address of the new library matches the static IP address that is saved in the cookie, the Web User Interface checks the serial number of the new library against the serial number that is saved in the cookie.
Page 79
4. It is necessary to change the serial number on the new library to the serial number of the old library to preserve your entitlement to IBM service. If you are with a static IP address, complete the following steps.
5. After physically installing and reconfiguring the new library, confirm that the library firmware installed is the latest version. Note the firmware revision number with the System Summary window of the Web User Interface and check against the latest firmware version at http://www-03.ibm.com/servers/storage/support. To update the library firmware, if necessary, see...
Replacement parts TS2900 Tape Autoloader has customer replaceable units (CRUs) that must be added, removed, and replaced by the customer. If you choose to have the CRU added, removed, or replaced by an IBM® service representative, there is a charge for the service.
Make a copy of this form, and fill it out as you are installing and configuring your library. Update the form each time changes are made to the library configuration. The information that is contained on this form is important, and helpful if a call to IBM® service is necessary.
To ensure that your IBM Ultrium Tape Drive conforms to IBM's specifications for reliability, use only IBM LTO Ultrium tape cartridges. You might use other LTO-certified data cartridges, but they might not meet the standards of reliability that are established by IBM. The IBM LTO Ultrium Data Cartridge cannot be interchanged with the media used in other IBM non-LTO Ultrium tape products.
An IBM Ultrium Universal Cleaning Cartridge is required to clean the tape drive. Cartridge memory chip (LTO-CM) All generations of the IBM LTO Ultrium data cartridges include a Linear Tape-Open Cartridge Memory (LTO-CM) chip. Bar code labels Bar code label requirements for LTO drives.
If an uninitialized M8 cartridge is not initialized in a tape library that supports uninitialized M8 cartridges, then the cartridge might inadvertently and silently be initialized at the L7 density (that is, at a 6 TB native capacity) even if the bar code label states “M8”. This action might occur with the usage of non-TS2900 Tape Autoloaders, stand- alone LTO-7 tape drives, stand-alone LTO-8 tape drives, earlier LTO-8 tape drive firmware, earlier TS2900 Tape Autoloader firmware, or earlier ISV software that does not...
Important: The drive must be cleaned only when it is requested by the drive. The IBM Ultrium Universal Cleaning Cartridge is valid for 50 uses. The cartridge's LTO-CM (Cartridge Memory) chip tracks the number of times that the cartridge is used.
Apply the following guidelines whenever using bar code labels: Use only IBM approved bar code labels on cartridges to be used in an IBM® tape library. Do not reuse a label or reapply a used label over an existing label.
Incorrect handling or an incorrect environment can damage cartridges or their magnetic tape. To avoid damage to your tape cartridges and to ensure the continued high reliability of your IBM® LTO Ultrium Tape Drives, use the following guidelines. Provide training Providing training to the users of your tape drive can prolong the life of your tape cartridges.
). If there are gaps in the seam (see Figure 1), the leader pin might be dislodged. Go to Repositioning or reattaching a leader pin. Figure 1. Checking for gaps in the seams of a cartridge 84 TS2900 Tape Autoloader...
If the leader pin in your cartridge becomes dislodged from its pin-retaining spring clips or detaches from the tape, you must use the IBM Leader Pin Reattachment Kit (part number 08L9129) to reposition or reattach it. (Do not reattach the pin if you must remove more than 7 meters (23 feet) of leader tape). The sections that follow describe each procedure.
5. To rewind the tape, insert the cartridge manual rewind tool ( 1 in Figure 3) into the cartridge's hub 2 and turn it clockwise until the tape becomes taut. Figure 3. Rewinding the tape into the cartridge 86 TS2900 Tape Autoloader...
Attention: Use only the IBM Leader Pin Reattachment Kit to reattach the leader pin to the tape. Other methods of reattaching the pin damages the tape, the drive, or both. Use this procedure on your tape cartridge only when the leader pin detaches from the magnetic tape and you must copy the cartridge's data onto another cartridge.
15. Remove the rewind tool. 16. Remove the leader pin attach tool by lifting up its end and away from the cartridge. Environmental and shipping specifications for tape cartridges Specific storage and shipping environmental conditions apply to tape cartridges. 88 TS2900 Tape Autoloader...
Machine Type 3589 Model 653 and FC 6507. You can also order through an IBM media Authorized Distributor. 18 TB Ultrium 9 WORM Tape Cartridge Labeled Order as part number 02XW569L through an IBM media Authorized Distributor. 18 TB Ultrium 9 WORM Tape Cartridge Order as part number 02XW569 through an I IBM media Authorized Distributor.
Page 95
Methods of Ordering 9 TB Ultrium 7 Uninitialized Data Cartridge M8 Order the cartridge from your IBM Sales Representative or any authorized IBM Business Partner by specifying (labeled) 20-PACK Machine Type 3589 Model 452. Specify the VOLSER characters that you want.
Replacement parts TS2900 Tape Autoloader has customer replaceable units (CRUs) that must be added, removed, and replaced by the customer. If you choose to have the CRU added, removed, or replaced by an IBM® service representative, there is a charge for the service.
Web User Interface. Before the TS2900 Tape Autoloader can be managed over a network with the Web User Interface, you must set up the initial network configuration of the library with the Operator Panel. For more information, see Configuring network...
Page 98
Remove the large black screws 11 from each front bracket that secure the front of the library to the rack, and slide the library chassis out of the rack (Figure Figure 5. Removing screws at the rear of the library TS2900 Tape Autoloader 93...
Figure 6. Library chassis cover screw locations 6. Lift the library chassis cover off vertically (Figure Figure 7. Library chassis cover removal Installation is the reverse of the removal procedure. Internal view of library Figure 8. Internal components 94 TS2900 Tape Autoloader...
Page 100
6. Remove the cartridge magazine from the library. 7. Remove the drive mounting screws from the sides of the tape drive housing. Two screws are on each side of the drive (Figure 10). Figure 10. Drive housing screw locations TS2900 Tape Autoloader 95...
Page 101
1. The best solution for recovering data on a damaged cartridge is to send it to IBM® for professional data recovery. 2. Before with this procedure, you must exhaust all other means of removing the tape cartridge from the drive. Use this procedure only if you cannot remove the tape cartridge by with any other means.
4. Moisten a cotton swab with water and wet approximately 13 mm (0.5 in.) of the tape end and feed it onto the supply reel (inside the cartridge). 5. Turn the supply reel ( 4 in Figure 1 clockwise, allowing the moistened tape to adhere to the hub as it winds around the supply reel (inside the cartridge). Figure 1. Rewinding tape into cartridge TS2900 Tape Autoloader 97...
7. Rotate the threader intermediate gear ( 1 in Figure 1) counterclockwise until the leader block is in front of the read/write head. This procedure moves the LBA out of the cartridge. Figure 2. Leader Block Assembly (LBA) 98 TS2900 Tape Autoloader...
Tape spooled off supply reel Tape pulled from or broken near leader pin Tape broken in mid-tape 2. Set the drive on its left side with the head and tape path facing up. Figure 1. Rewinding tape into cartridge TS2900 Tape Autoloader 99...
Figure 2) and slowly rotate the threader mechanism gear ( 2 in Figure 2) clockwise. This procedure draws the tape leader block assembly (LBA) into the cartridge. Figure 2. Drive with cover removed to reveal gear train 100 TS2900 Tape Autoloader...
2. Reinstall the library chassis cover. See Removing or reinstalling the library chassis cover. 3. Return the defective library to IBM®. Removing a stuck cartridge magazine Complete the following steps to remove a stuck cartridge magazine from the library: 1. Turn OFF the power to the library.
Page 107
While the data shows a TAPE_ERR2, it might be caused by a library failure. When you attempt a Move Medium command ("A5"), the ASC/ASCQ points to a "Mechanical Positioning Error". For more information about sense data, see the IBM LTO Ultrium Tape Drive SCSI Reference.
Page 108
FID was listed ("86") defines the failure as "The drive detected a drive hardware or media fault". In this case, follow the FID to make a repair. For more information about Sense Key and ASC/ASCQ fields, see the IBM LTO Ultrium Tape Drive SCSI Reference.
FID (FRU identification number). In this case, a Drive Hardware or Media problem. Retrieving from an IBM System i with RISC processor IBM® device drivers for the System i® operating system logs error information when an error occurs on a tape drive or library. The error information includes:...
Page 110
IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used.
Page 111
For example, the products only provide IBM data about the asset usage and configuration and do not reflect private use of the asset. When diagnostics are required to be sent to IBM, and a problem is submitted, that data is routed directly to a secured infrastructure.
IBM reserves the right to withdraw the permissions that are granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or as determined by IBM, the above instructions are not being properly followed.
Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
Page 114
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. IBM® is not responsible for any radio or television interference caused by using other than recommended cables and connectors, or by unauthorized changes or modifications to this equipment.
Rack safety Power cords For your safety, IBM® provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet. Cautions and regulatory compliance statements for NEBS This library is NEBS certified.
CAUTION: The battery is a lithium ion battery. To avoid possible explosion, do not burn. Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM® has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
Page 117
Ensure that no stabilizer bracket is installed on the rack cabinet during movement. Do not use a ramp that is inclined at more than 10 degrees. When the rack cabinet is in the new location, complete these steps. Lower the four leveling pads. 112 TS2900 Tape Autoloader...
Gravity (CoG) higher than 22U. (R011) Power cords For your safety, IBM® provides a power cord with a grounded attachment plug to use with this IBM product. To avoid electrical shock, always use the power cord and plug with a properly grounded outlet.
Page 119
Authentication Header. An Internet Protocol intended to guarantee connectionless integrity and data origin authentication of IP datagrams. Further, it can optionally protect against replay attacks by using the sliding window technique and discarding old packets. Advanced Interactive Executive. IBM's implementation of the UNIX operating system. The System p system, among others, uses AIX as its operating system. alphanumeric Pertaining to a character set that contains letters, numerals, and other characters, such as punctuation marks.
Page 120
A drive that communicates messages from the host computer to the library in which the drive is installed. cookie A packet of data that is exchanged between the library and a web browser to track configuration. TS2900 Tape Autoloader 115...
Page 121
Drive Not Configured This message occurs during the first boot after a factory settings restore is run. This message is not a real issue since it takes time for the library to configure. Drive. DSA key 116 TS2900 Tape Autoloader...
Page 122
firmware to encrypt and decrypt host tape application data. Encryption policy and encryption keys are provided by the host application or host server. encryption key manager (EKM) A Java™ software program that assists IBM-encrypting tape drives in generating, protecting, storing, and maintaining encryption keys that encrypt information that is written to and decrypt information that is read from tape media.
Page 123
IBM Ultrium Tape Drive Located within the library, a data-storage device that controls the movement of the magnetic tape in an IBM LTO Ultrium Tape Cartridge. The drive houses the mechanism (drive head) that reads and writes data to the tape.
Page 124
Library Control Blade See liquid crystal display. LDAP Lightweight Directory Access Protocol. This allows the library to use login and password information that is stored on a server to grant access to the library functionality. LDAPS TS2900 Tape Autoloader 119...
Page 125
Pertaining to the bar code on the bar code label of the IBM Ultrium Tape Cartridge, a 2-character code, L1, that represents information about the cartridge. L identifies the cartridge as one that can be read by devices that incorporate LTO technology; 1 indicates that it is the first generation of its type.
Page 126
CD-ROM), and can be viewed with the Acrobat Reader, which is software from Adobe Systems that can be downloaded at no cost from the Adobe Systems home page. Private key TS2900 Tape Autoloader 121...
Page 127
Serial Attached SCSI. A computer bus technology and serial communication protocol for direct attached storage devices. SAS is a replacement for parallel SCSI with higher speeds, but still utilizing SCSI commands. scratch cartridge A data cartridge that contains no useful data, but can be written to with new data. Single Character Display. SCSI Small computer system interface. Single-ended. segment 122 TS2900 Tape Autoloader...
Page 128
SMI-S is to enable broad interoperable management of heterogeneous storage vendor systems. subsystem A secondary or subordinate system, capable of operating independently of, or asynchronously with, a controlling system. SUPP Support. sync Synchronous, synchronize. Occurring with a regular or predictable time relationship. TS2900 Tape Autoloader 123...
Page 129
System-managed encryption Tape encryption is set up implicitly through the IBM device driver. tachometer, tach A device that emits pulses that are used to measure/check speed or distance. tape cartridge A container that holds magnetic tape, that can be processed without separating it from the container.
This topic lists sources that provide additional information about the TS2900 Tape Autoloader. Note: The TS2900 Tape Autoloader is a customer installed unit. The customer is responsible for the setup and maintenance of the tape autoloader. The customer is charged for service if a service contract isn’t in place.