Table 13. Location criteria
Criteria
Room temperature
Voltage
Frequency
Relative humidity
Air quality
Clearance
Rack requirements

Acclimation

|
Server and storage equipment (racks and frames) must be gradually acclimated to the surrounding
|
environment to prevent condensation.
|
When server and storage equipment (racks and frames) is shipped in a climate where the outside
|
temperature is below the dew point of the destination (indoor location), there is a possibility that water
|
condensation can form on the cooler inside and outside surfaces of the equipment when the equipment is
|
|
brought indoors.
Sufficient time must be allowed for the shipped equipment to gradually reach thermal equilibrium with
|
|
the indoor environment before you remove the shipping bag and energize the equipment. Follow these
guidelines to properly acclimate your equipment:
|
v Leave the system in the shipping bag. If the installation or staging environment allows it, leave the
|
product in the full package to minimize condensation on or within the equipment.
|
22
IBM TS2900 Tape Autoloader: Setup, Operator, and Service Guide Machine Type 3572
Definition
16 - 32 °C (60 - 90 °F)
100 - 240 Vac. (4.0 to 1.5 A)
Note: The power switch is on the rear of the library and
must be easily accessible.
50 - 60 Hz
20 - 80% non-condensing
The library must be placed in an area with minimal
sources of particulate contamination. Avoid areas near
frequently used doors and walkways, stacks of supplies
that collect dust, printers, and smoke-filled rooms.
Excessive dust and debris can damage cartridges and the
tape drive.
v Back: Minimum of 15 cm (6 in.)
v Front: Minimum of 30 cm (12 in.)
v Sides: Minimum of 5 cm (2 in.)
Standard EIA 19-inch rack: 1U space