Library Sense Data - IBM TS2900 Setup, Operator, And Service Manual

Tape autoloader (machine type 3572)
Hide thumbs Also See for TS2900:
Table of Contents

Advertisement

Library sense data

"Library sense data" lists the Additional Sense Codes (ASC) and Additional Sense Code Qualifiers
(ASCQ) associated with the reported Sense Keys.
A sense key of 00h (no sense) has no ASC/ASCQ associated with it. A few ASC/ASCQs are associated
with more than one sense key. The sense keys that can give a particular ASC/ASCQ are indicated within
the Sense Key column.
Table 39. Library sense data
Sense Key
No Sense (00)
Recovered Error (01)
Not Ready (02)
Hardware Error (04)
Illegal Request (05)
Unit Attention (06)
208
IBM TS2900 Tape Autoloader: Setup, Operator, and Service Guide Machine Type 3572
ASC
ASCQ
00
00
30
03
5B
02
04
00
04
01
04
03
3A
02
80
05
15
01
40
nn
44
00
53
00
80
07
1A
00
20
00
21
01
24
00
25
00
26
00
30
00
3B
0D
3B
0E
3B
83
53
02
80
10
80
20
80
21
28
00
28
01
29
00
2A
02
3F
01
41
FE
Description
No sense
Cleaning cartridge installed
Log counter at maximum
Logical unit not ready, cause not reportable
Logical unit is in process of becoming ready
Manual intervention required
Media not present (tray open)
During reprogramming mode
Mechanical position error
Diagnostic failure on component nn (80h-ffh)
Internal target failure
Media load or eject failed
NVRAM failure
Parameter list length error
Invalid command operation code
Invalid element address
Invalid field in CDB
Logical unit not supported
Invalid field in parameter list
Incompatible medium installed
Media destination element full
Media source element empty
Source drive not unloaded
Media removal prevented
Drive failure
Exchange slot full
Cartridge wrong insertion
Not-ready to ready transition, media may
have changed
Import or export element accessed
Power ON occurred
Log parameter changed
Microcode has been changed
Drive error message detected*

Advertisement

Table of Contents
loading