Table 32. Library error codes (continued)
Code (H)
Description
No media is contained in the
specified cell (Cell Empty).
00B1
Suspect the centering sensor, X
motor, or P motor.
Media detected in the accessor at
completion of centering check
00B2
operation. Suspect the centering
sensor.
Media detected in the accessor at
00B3
completion of PUT operation.
Suspect the centering sensor.
accessor error #1.
Reverse REV position (PP1) error
(accessor origin not detected or
00B8
FWD position detected). Suspect
the P origin sensor, FWD sensor,
or P motor.
accessor error #2.
Forward FWD position (PP2)
error (accessor origin detected or
00B9
FWD not detected). Suspect the P
origin sensor, FWD sensor, or P
motor.
accessor error #3.
PUT/GET/bar code reader
position (PP4/PP5/PPBF/PPBR)
00BA
error (accessor origin or FWD
detected, or cell full). Suspect the
P origin sensor, FWD sensor, or P
motor.
During initialization, the accessor
origin could not be detected.
00BC
Suspect the P origin sensor, FWD
sensor, or P motor.
During accessor movement, the
movement stop condition
00BD
detected. Suspect the P encoder
sensor or P motor.
No gap condition detected at the
completion of accessor operation.
00BF
Suspect the centering sensor, P
origin sensor, FWD sensor, or P
motor.
Panel Indication
Cycle the power supply and try again.
v If the problem is corrected, run Library Verify
CHK 00B1
before normal library operations resume.
v If the problem persists, see "Contacting IBM
technical support" on page 139.
1. If the cartridge remains in the accessor, try to
move the cartridge from the accessor to the
I/O Station with the Operator Panel or Web
CHK 00B2
User Interface. Remove the cartridge from
the library and inspect for damage and
replace, if necessary.
2. Cycle the power supply and try again.
v If the problem is corrected, run Library
Verify before normal library operations
CHK 00B3
resume.
v If the problem persists, see "Contacting
IBM technical support" on page 139.
1. Check the accessor locking screw and
remove it if it is installed. See "Removing the
accessor locking screw" on page 33.
CHK 00B8
2. Cycle the power supply and try again.
v If the problem is corrected, run Library
Verify before normal library operations
resume.
v If the problem persists, see "Contacting
IBM technical support" on page 139.
CHK 00B9
CHK 00BA
CHK 00BC
CHK 00BD
CHK 00BF
Action Required
Appendix B. Error codes
193