IBM TS2900 Setup, Operator, And Service Manual page 217

Tape autoloader (machine type 3572)
Hide thumbs Also See for TS2900:
Table of Contents

Advertisement

Table 32. Library error codes (continued)
Code (H)
Description
Calibration failed due to an
0071
empty magazine. Suspect the
magazine set sensor.
Calibration measurement invalid
0072
data error. Suspect the centering
sensor, X motor, or P motor.
GET, centering check, or bar code
reader read operation failed
0074
because the accessor contains
media. Suspect the centering
sensor.
PUT operation failed because the
0075
accessor contains no media.
Suspect the centering sensor.
Drive does not enter EJECT state
(and media not ejected) within
007C
200 seconds of a GET command.
Suspect the drive.
Drive does not enter MOUNT
state within 200 seconds of a PUT
007D
command. Suspect the drive or X
motor.
Drive does not enter SET state
within 3 seconds of a PUT
007E
command. Suspect the drive or X
motor.
Drive I/F or connection error
007F
occurs during a PUT operation or
GET operation. Suspect the drive.
Panel Indication
Cycle the power supply and try again.
CHK 0071
v If the problem is corrected, run Library Verify
before normal library operations resume.
v If the problem persists, see "Contacting IBM
CHK 0072
technical support" on page 139.
CHK 0074
CHK 0075
1. If the cartridge does not eject, try to unload
the cartridge from the drive with the
Operator Panel (Commands > Unload) or
the Web User Interface (Manage Library >
Unload). Move the cartridge from the drive
to the I/O Station. Remove the cartridge
from the library and inspect for damage and
CHK 007C
replace, if necessary.
2. Cycle the power supply and try again.
v If the problem is corrected, run Library
Verify before normal library operations
resume.
v If the problem persists, see "Contacting
IBM technical support" on page 139.
Cycle the power supply and try again.
v If the problem is corrected, run Library Verify
CHK 007D
before normal library operations resume.
v If the problem persists, see "Contacting IBM
technical support" on page 139.
CHK 007E
1. Reseat all cables. See "Reseating cables" on
page 137.
2. Cycle the power supply and try again.
v If the problem is corrected, run Library
CHK 007F
Verify before normal library operations
resume
v If the problem persists, see "Contacting
IBM technical support" on page 139.
Action Required
Appendix B. Error codes