Managing The Library; Moving Cartridges; Move Cartridges Screen - IBM TS2900 Setup, Operator, And Service Manual

Tape autoloader (machine type 3572)
Hide thumbs Also See for TS2900:
Table of Contents

Advertisement

Managing the library

Moving cartridges

|
|
|
Figure 82. Move Cartridges screen
|
Use Manage Library > Move Cartridges to move data and cleaning cartridges between the I/O station,
storage positions, inactive slots, and tape drive. Move cartridges using either of two methods:
|
|
v Click and drag a cartridge from one location to another.
|
v Click a cartridge, select location coordinates from the Destination slot menu, and click Move.
clicking and dragging a cartridge from one location to another, or by clicking a cartridge and selecting a
cartridge coordinate from the Destination slot menu, and clicking Move.
Select a cartridge to display information for that cartridge in the Source pane on the right side of the
page. Drag the cartridge to a valid destination location to display information in the Destination pane.
Release the mouse button to run the move.
The following information is displayed:
v Source
– Drive or location coordinates (Column, Tier) in the library ([Cn,Tn] : Cartridge Label)
– Column n, Tier n Information
- Element address
- Slot type (Storage, I/O station, or Cleaning / Inactive)
|
– Drive Information
- Status (Ok or Empty)
– Cartridge Information
- Media status (OK, Degraded, or Failed)
- Cartridge label
- Encryption capability for storage cartridges (Unknown, Encrypted, or Not encrypted)
- Write protect (Yes or No)
|
79