Sinamics G120D Specifications - Siemens SINAMICS G120D Operating Instructions Manual

With control units cu250d-2
Hide thumbs Also See for SINAMICS G120D:
Table of Contents

Advertisement

Technical data

11.3 SINAMICS G120D specifications

Feature
Brake voltage
Standby current
11.3
SINAMICS G120D specifications
Power Module Specifications
Table 11- 3
Power Module Frame Sizes A and B, 3 AC 380 V ... 500 V, ± 10 %
Order No.
Output Rating (HO)
Output Power
Rated Input Current
HO Output Current
Weight (nett)
Weight (packed)
Table 11- 4
Power Module Frame Sizes C, 3 AC 380 V ... 500 V, ± 10 %
Order No.
Output Rating (HO)
Output Power
Rated Input Current
HO Output Current
Weight (nett)
Weight (packed)
348
Specification
180 V DC (400 V half-wave rectified) 1 A maximum
The UL approved current rating for the brake output is 600 mA.
If the converter is powered-up, but the motor is still switched off, the con-
verter requires a standby current.
You have to consider the standby current when calculating the size of the
conductors and selecting the correct protective devices on the line supply.
For more comprehensive information on the standby current, please read
the following FAQ: Standby currents for PM250D
(http://support.automation.siemens.com/WW/view/en/31764702).
6SL3525 -
0PE17-5AA1
[kW]
[kVA]
[A]
[A]
[kg]
[lbs]
[kg]
[lbs]
6SL3525 -
0PE24-0AA1
[kW]
[kVA]
[A]
[A]
[kg]
[lbs]
[kg]
[lbs]
0PE21-5AA1
0.75
1.5
2.1
3.8
2.2
4.1
5.5
5.5
12.1
12.1
6.5
6.5
14.3
14.3
0PE25-5AA1
4
5.5
9.5
12.2
10.2
13.2
9.5
9.5
20.9
20.9
10.5
10.5
23.1
23.1
Operating Instructions, 04/2015, FW V4.7.3, A5E34261542B AB
0PE23-0AA1
3
7.2
7.7
8.5
18.7
9.5
20.9
0PE27-5AA1
7.5
17.7
19
9.5
20.9
10.5
23.1
Converter with control units CU250D-2